Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: In the US, the HIV diagnostic algorithm for laboratory settings recommends the use of an HIV-1/HIV-2 differentiation supplemental assay after an initial reactive antigen/antibody (Ag/Ab) assay result. Since the discontinuation of the Multispot HIV-1/HIV-2 Rapid Test (MS), the Geenius HIV-1/2 Supplemental assay (Geenius) is the only FDA-approved supplemental differentiation test.
Objective: We compared the performance of Geenius to MS and Western Blot (WB).
Study Design: The relative seroconversion plasma reactivity of Geenius and MS was assessed using a 50% cumulative frequency analysis from 17 HIV-1 seroconverters. In addition, previously characterized plasma specimens, 186 HIV-1 positive, 100 HIV-2 positive, and 93 Ag/Ab-positive/HIV-1 RNA-negative, were tested with Geenius v1.1 software. McNemar's test was used for paired comparison analysis. A subset of 48 specimens were retested with the upgraded Geenius v1.3 software.
Results: In HIV-1 seroconverters, the relative seroconversion reactivity was 2.5 and 2 days before the first positive HIV-1 WB for Geenius and MS, respectively. In HIV-1 positive samples, Geenius performed similarly to HIV-1 WB (p=0.1687) and MS (p=0.8312). In HIV-2 positive samples, Geenius underperformed compared to HIV-2 WB (p=0.0005) and MS (p=0.0012). When using the upgraded software among the HIV-1 positive and Ag/Ab-reactive/HIV-1 RNA-negative samples, gp140 reactivity decreased without affecting characterization of HIV-2 samples.
Conclusions: With HIV-1 samples, Geenius, WB and MS performance was similar as supplemental tests. The updated Geenius software reduced false gp140 reactivity, but had no impact on identifying true HIV-2 infections. Further evaluation will assess the impact of the Geenius software update on final diagnostic interpretations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcv.2018.12.006 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!