[Evaluation of a screening test for urinary infection].

Pathol Biol (Paris)

Laboratoire de Bactériologie, Hôpital Trousseau, Centre Hospitalier Universitaire de Tours, France.

Published: September 1988

AI Article Synopsis

Article Abstract

The interest of using a reagent strip (Multistix-8 SG, Ames, Miles Laboratories) as a screen for urinary tract infection was evaluated in a clinical study involving several sites and 2,183 adult urine specimens of which 340 were infected. The results are expressed in terms of sensitivity, specificity, predictive value of a negative and positive test. The predictive value of a negative test for nitrites in combination with leucocytes (97.5%) justifies the use of the reagent strip in eliminating non-infected urine.

Download full-text PDF

Source

Publication Analysis

Top Keywords

reagent strip
8
predictive negative
8
[evaluation screening
4
screening test
4
test urinary
4
urinary infection]
4
infection] interest
4
interest reagent
4
strip multistix-8
4
multistix-8 ames
4

Similar Publications

Currently commercial colorimetric paper lateral flow immunoassays exhibit insufficient limit of detection (LOD) and limited clinical sensitivity toward the detection of SARS-CoV-2 antigens, which causes a high false negative rate. To mitigate this issue, a new plasmon-enhanced fluorescence probe was developed for paper lateral flow strips (PLFSs). The probe is made of a sandwich-structured Ag-core@silica@dye@silica-shell nanoparticle in which fluorescent dyes are sandwiched between the plasmonic Ag core and the silica outer shell, and the separation distance between the Ag core and the dye molecules is controlled by the silica space layer.

View Article and Find Full Text PDF

Rapid detection of hydrogen peroxide and nitrite in adulterated cow milk using enzymatic and nonenzymatic methods on a reusable platform.

RSC Adv

January 2025

Environmental Biotechnology Laboratory, Department of Biological Sciences, Birla Institute of Technology and Science Pilani, Hyderabad Campus, Jawahar Nagar, Kapra Mandal, Medchal District Hyderabad 500078 India

Cow milk is readily adulterated due to its complex properties that can emulsify many adulterants. Among the commonly used adulterants in cow milk are hydrogen peroxide (HP) and nitrite. Commercially available HP is added to extend cow milk's shelf life, while nitrite enters through the tap or pond water added to increase cow milk's volume.

View Article and Find Full Text PDF

Background And Aim: In animal husbandry, antibiotics are frequently used as growth promoters, as well as for illness prevention and treatment. They are considered important toxic and allergenic contaminants of food and a serious risk factor for the spread of antibiotic resistance. National and international regulatory authorities have established limits on the permissible residue of antibiotics in food.

View Article and Find Full Text PDF

Background: One method for noninvasive and simple urinary microalbumin testing is urine test strips. However, when visually assessing urine test strips, accurate assessment may be difficult due to environmental influences-such as lighting color and intensity-and the physical and psychological influences of the assessor. These complicate the formation of an objective assessment.

View Article and Find Full Text PDF

A POCT assay based on commercial HCG strip for miRNA21 detection by integrating with RCA-HCR cascade amplification and CRISPR/Cas12a.

Mikrochim Acta

January 2025

Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, China.

A point-of-care testing (POCT) assay based on commercial HCG strip was proposed for miRNA21 detection by integrating RCA-HCR cascaded isothermal amplification with CRISPR/Cas12a. Three modules were integrated in the proposed platform: target amplification module composed of rolling circle amplification (RCA) cascaded with hybridization chain reaction (HCR), signal transduction module composed of CRISPR/Cas12a combined with HCG-agarose gel beads probes, and signal readout module composed of commercial HCG strips. The proposed RCA-HCR-CRISPR/Cas12a-HCG strip assay for miRNA21 detection had high sensitivity, and the limit of detection was as low as 37 fM.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!