Aims: Although a recent expert consensus statement has recommended periprocedural uninterrupted (UI) non-vitamin K antagonist oral anticoagulants (NOACs) during catheter ablation of atrial fibrillation (AF) as a Class I indication, there have been no clear randomized trials. We investigated the safety and efficacy of UI, procedure day single-dose skipped (SDS), and 24-hour skipped (24S) NOACs in patients undergoing AF ablation.
Methods And Results: In this prospective, open-label, randomized multicentre trial, 326 patients (75% male, 58 ± 11 years old) scheduled for AF catheter ablation were randomly assigned in a 1:1:1 ratio to UI, SDS, and 24S at three tertiary hospitals. Bridging with low molecular weight heparin was carried out in the patients with persistent AF who were assigned to the 24S group. Dabigatran, rivaroxaban, and apixaban were assigned in order after randomization. The primary endpoint was the incidence of bleeding events within 1 month after ablation. The secondary endpoints included thrombo-embolic and other procedure-related complications. The intra-procedural heparin requirement was higher in the 24S group than others (P < 0.001), and the mean activated clotting time was comparable among the groups (P = 0.139). The incidence of major bleeding up to 1 month after ablation and a post-procedural reduction in the haemoglobin levels did not significantly differ among the treatment groups and different NOACs (P > 0.05). There were no fatal events or thrombo-embolic complications in all the three groups.
Conclusion: In patients undergoing AF ablation, UI NOACs and SDS or double dose skipped NOACs had a comparable efficacy and safety, regardless of the type of NOAC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/eurheartj/ehy870 | DOI Listing |
Rev Port Cardiol
January 2025
Cardiology Department, Hospital Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal.
Introduction And Objectives: Pulmonary vein (PV) isolation is one of the cornerstones of rhythm-control therapy for symptomatic atrial fibrillation (AF) patients. Pulsed field ablation (PFA) is a novel ablation modality that involves the application of electrical pulses causing cellular death, and it has preferential tissue specificity. In this study, we aimed to share a one-year single center experience of AF ablation with PFA.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Pacing Clin Electrophysiol
January 2025
Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin, USA.
Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Department of Cardiology, Yan'an Hospital Affiliated to Kunming Medical University, Kunming, Yunnan, P.R. China.
Objective: The Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Section of Laboratory for Animal Experiments, Institute of Medical Science, Medical Research Support Center, Nihon University, School of Medicine, Tokyo, Japan.
Background: Neither the actual in vivo tissue temperatures reached with a novel contact force sensing catheter with a mesh-shaped irrigation tip (TactiFlex SE, Abbott) nor the safety profile has been elucidated.
Methods: In a porcine model (n = 8), thermocouples were implanted epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava following a right thoracotomy. After chest closure, endocardial ablation was conducted near the thermocouples under fluoroscopic guidance.