Introduction: The monitoring of factor VIII (FVIII) replacement therapy relies on the accurate measurement of FVIII activity over a large concentration range. However, unexplained overestimation of low FVIII levels has recently been reported with extended half-life recombinant FVIIIs.

Aim: The objective of this study was to confirm previous publications indicating that the reagents used to generate the calibration curves determine the accuracy of the measurement of low FVIII levels.

Methods: We generated FVIII calibration curves with FVIII-deficient plasmas or a commercial diluent buffer. We then measured FVIII levels in FVIII-deficient plasma spiked with plasma FVIII, a full-length recombinant FVIII (Advate , Shire, Brussels, Belgium) and two extended half-life recombinant FVIIIs (Elocta , Swedish Orphan Biovitrum, Woluwe Saint-Lambert, Belgium and Afstyla , CSL Behring, Mechelen, Belgium). FVIII levels were also analyzed in spiked samples prediluted two- and fourfold, either in diluent buffer or in FVIII-deficient plasma to evaluate parallelism.

Results: Coagulation times of calibration curves generated with diluent buffer were longer than those with FVIII-deficient plasmas. This resulted in an overestimation of FVIII levels lower than 25 IU/dL in spiked samples and in detection of FVIII activity (≥1 IU/dL) in FVIII-deficient plasma. Predilution of samples with diluent buffer rather than with FVIII-deficient plasma also led to discordant results.

Conclusion: Our data confirm that the generation of calibration curves by dilution in FVIII-deficient plasma is crucial for the accurate measurement of low FVIII levels. When serial dilutions of samples are analyzed, predilution in FVIII-deficient plasma is required to respect the parallelism criteria. These methods should be more generally implemented for coagulation instruments.

Download full-text PDF

Source
http://dx.doi.org/10.1111/hae.13656DOI Listing

Publication Analysis

Top Keywords

fviii-deficient plasma
24
calibration curves
20
fviii levels
20
diluent buffer
16
fviii
13
accurate measurement
12
extended half-life
12
low fviii
12
factor viii
8
fviii activity
8

Similar Publications

Background: The incidence of cardiovascular diseases is increasing in persons with hemophilia A (HA). Therefore, anticoagulant therapy based on direct oral anticoagulants (DOACs) may be needed, despite the bleeding risk. In case of surgery or bleeding, such patients may be concomitantly treated with emicizumab (routine prophylaxis), factor (F)VIII products, and DOAC.

View Article and Find Full Text PDF
Article Synopsis
  • The patient received multiple doses of rFVIIa around the time of surgery, and there were no bleeding or thrombotic complications reported during and after the operation.
  • The study suggests that using rFVIIa every 8 hours may be effective for managing bleeding risks in patients treated with emicizumab during surgery.
View Article and Find Full Text PDF

Background:  Bypassing agents are used for breakthrough bleedings in patients with hemophilia A with inhibitor (PwHAwI) receiving emicizumab prophylaxis. Previous study demonstrated a weak binding affinity between emicizumab and factor (F)X ( ; 1.85 μM), and that this value was much greater than the plasma FX concentration (∼130 nM).

View Article and Find Full Text PDF

Introduction: An investigation of the suitability of reagents for measuring FVIII products in a one-stage clotting assay (OSA) showed variations in their FVIII activity (FVIII:C). Most studies have focused on the activated partial thromboplastin time (APTT) reagent rather than FVIII-deficient plasma (F8DP), even though the APTT-based OSA is comprised of APTT reagents and factor-deficient plasma.

Aim: A single-centre study was conducted to clarify variations in measurements of FVIII products in an OSA using a total of 12 reagent combinations, including four APTT reagents and three types of F8DP.

View Article and Find Full Text PDF

Introduction: Recombinant porcine factor VIII (rpFVIII) is a treatment option for break-through bleeds in patients with congenital haemophilia A with inhibitors (CHAwI) on emicizumab. However, there are limited data about the measurement of rpFVIII in the presence of emicizumab.

Aim: To analyse whether rpFVIII can be measured with a chromogenic assay with bovine component (bCSA) in plasma from CHAwI on emicizumab treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?