A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel dynamical approach in continuous cuffless blood pressure estimation based on ECG and PPG signals. | LitMetric

Continuous cuffless blood pressure (BP) monitoring has attracted much interest in finding the ideal treatment of diseases and the prevention of premature death. This paper presents a novel dynamical method, based on pulse transit time (PTT) and photoplethysmogram intensity ratio (PIR), for the continuous cuffless BP estimation. By taking the advantages of both the modeling and the prediction approaches, the proposed framework effectively estimates diastolic BP (DBP), mean BP (BP), and systolic BP (SBP). Adding past states of the cardiopulmonary system as well as present states of the cardiac system to our model caused two main improvements. First, high accuracy of the method in the beat to beat BP estimation. Second, notwithstanding noticeable BP changes, the performance of the model is preserved over time. The experimental setup includes comparative studies on a large, standard dataset. Moreover, the proposed method outperformed the most recent and cited algorithms with improved accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.artmed.2018.12.005DOI Listing

Publication Analysis

Top Keywords

continuous cuffless
12
novel dynamical
8
cuffless blood
8
blood pressure
8
dynamical approach
4
approach continuous
4
pressure estimation
4
estimation based
4
based ecg
4
ecg ppg
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!