Trans-mitral blood flow produces a three-dimensional rotational body of fluid, known as a vortex ring, that enhances the efficiency of left ventricular (LV) filling compared with a continuous linear jet. Vortex ring development is most often quantified with vortex formation time (VFT), a dimensionless parameter based on fluid ejection from a rigid tube. Our group is interested in factors that affect LV filling efficiency during cardiac surgery. In this report, we describe how to use standard two-dimensional (2D) and Doppler transesophageal echocardiography (TEE) to noninvasively derive the variables needed to calculate VFT. We calculate atrial filling fraction (β) from velocity-time integrals of trans-mitral early LV filling and atrial systole blood flow velocity waveforms measured in the mid-esophageal four-chamber TEE view. Stroke volume (SV) is calculated as the product of the diameter of the LV outflow track measured in the mid-esophageal long axis TEE view and the velocity-time integral of blood flow through the outflow track determined in the deep transgastric view using pulse-wave Doppler. Finally, mitral valve diameter (D) is determined as the average of major and minor axis lengths measured in orthogonal mid-esophageal bicommissural and long axis imaging planes, respectively. VFT is then calculated as 4 × (1-β) × SV/(πD). We have used this technique to analyze VFT in several groups of patients with differing cardiac abnormalities. We discuss our application of this technique and its potential limitations and also review our results to date. Noninvasive measurement of VFT using TEE is straightforward in anesthetized patients undergoing cardiac surgery. The technique may allow cardiac anesthesiologists and surgeons to assess the impact of pathological conditions and surgical interventions on LV filling efficiency in real time.

Download full-text PDF

Source
http://dx.doi.org/10.3791/58374DOI Listing

Publication Analysis

Top Keywords

cardiac surgery
12
blood flow
12
vortex formation
8
formation time
8
transesophageal echocardiography
8
vortex ring
8
filling efficiency
8
measured mid-esophageal
8
tee view
8
outflow track
8

Similar Publications

Purpose: To develop an artificial intelligence (AI) algorithm for automated measurements of spinopelvic parameters on lateral radiographs and compare its performance to multiple experienced radiologists and surgeons.

Methods: On lateral full-spine radiographs of 295 consecutive patients, a two-staged region-based convolutional neural network (R-CNN) was trained to detect anatomical landmarks and calculate thoracic kyphosis (TK), lumbar lordosis (LL), sacral slope (SS), and sagittal vertical axis (SVA). Performance was evaluated on 65 radiographs not used for training, which were measured independently by 6 readers (3 radiologists, 3 surgeons), and the median per measurement was set as the reference standard.

View Article and Find Full Text PDF

Purpose: Vertebral body tethering (VBT) is a non-fusion surgical option for adolescent idiopathic scoliosis (AIS) that requires a postoperative (PO) chest tube. This study evaluates whether 48 h of PO TXA reduces chest tube (CT) drainage and retention compared to 24 h of TXA following VBT for AIS.

Methods: Consecutively treated patients with a diagnosis of AIS who underwent VBT were assessed.

View Article and Find Full Text PDF

The patient's mental health from the perspective of consultation-liaison psychiatry at the stage of qualification for mechanical circulatory support implantation.

Psychiatr Pol

October 2024

Śląskie Centrum Chorób Serca w Zabrzu; Katedra i Klinika Kardiochirurgii, Transplantologii, Chirurgii Naczyniowej i Endowaskularnej, Wydział Nauk Medycznych w Zabrzu, SUM w Katowicach.

During qualification for mechanical circulatory support, the comprehensive assessment of a patient's mental state is an integral element of the overall medical evaluation. It encompasses a range of psychosocial issues, and as such provides information helpful in the selection of a suitable candidate for the required treatment, and sometimes identifies contraindications to it. It allows ensuring that the patient meets expectations regarding both mental health stability and adherence to medical recommendations.

View Article and Find Full Text PDF

We demonstrate that performing anatomical pulmonary resection by video-assisted thoracoscopic surgery without staplers or energy devices is feasible. This technique is an alternative for surgeons with limited access to expensive technologies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!