Introduction: Cuff tear arthritis and complex proximal humeral fractures are common pathologies that are frequently addressed by the implantation of a reversed shoulder prosthesis. The present cadaveric study aimed to analyze the effect of cement augmentation of the glenoid component on the primary stability in geriatric patients.
Hypothesis: Cement augmentation of glenoid baseplate screws has an influence on primary stability in reversed shoulder arthroplasty (RSA).
Materials And Methods: Glenoid base plates (Delta Xtend, DePuy Synthes, Westchester, USA) were implanted in 6 pairs of formalin-fixated scapulae of 4 female and 2 male donors (average age 83 years). Two angle stable screws were placed at the superior and inferior position. Cement augmentation was performed with 2ml bone cement (Kyphon, Medtronic, Minneapolis, USA) per screw in right specimens. Afterwards, biomechanical testing with 600 to 1000N (100 cycles) at a 65° abduction angle was performed. Finally, a load-to-failure analysis was conducted.
Results: No implant loosening was observed during cyclic tests from 600N to 1000N. In addition no difference in the plastic deformation was detected at 600N (p=0.301), 700N (p=0.522), 800N (p=0.480), 900N (p=0.521) and 1000N (p=0.748). Load-to-failure analyses revealed implant loosening at 3314N (SD 823N) in the cement-augmented implants and at 3059N (SD 974N) in scapulae with non-cemented screws (p=0.522).
Discussion: Cement-augmented fixation of the glenoid component did not result in an increased primary stability in this study. Thus, the application of cement should be critically assessed considering associated risks and increased costs.
Level Of Proof: Basic science study, controlled laboratory study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.otsr.2018.10.006 | DOI Listing |
J Spine Surg
December 2024
Department of Orthopedic Surgery, Chung Shan Hospital, Taipei, Taiwan.
Background: Prone lateral spinal surgery for simultaneous lateral and posterior approaches has recently been proposed to facilitate surgical room efficiency. The purpose of this study is to evaluate the feasibility and outcomes of minimally invasive prone lateral spinal surgery using a rotatable radiolucent Jackson table.
Methods: From July 2021 to June 2023, a consecutive series of patients who received minimally invasive prone lateral spinal surgery for various etiologies by the same surgical team were reviewed.
Spine J
January 2025
Medical University of South Carolina, Charleston, SC, USA. Electronic address:
Background Context: Clinical outcomes are directly related to patient selection and treatment indications for improved quality of life. With emphasis on quality and value, it is essential that treatment recommendations are optimized.
Purpose: The purpose of the North American Spine Society (NASS) Appropriate Use Criteria (AUC) is to determine the appropriate (ie, reasonable) multidisciplinary treatment recommendations for patients with metastatic neoplastic vertebral fractures across a spectrum of more common clinical scenarios.
J Bone Joint Surg Am
January 2025
Department of Orthopaedics, BenQ Medical Center, The Affiliated BenQ Hospital of Nanjing Medical University, Nanjing, Jiangsu, People's Republic of China.
Background: No studies have evaluated the impact of the cement distribution as classified on the basis of the fracture bone marrow edema area (FBMEA) in magnetic resonance imaging (MRI) on the efficacy of percutaneous vertebral augmentation (PVA) for acute osteoporotic vertebral fractures.
Methods: The clinical data of patients with acute, painful, single-level thoracolumbar osteoporotic fractures were retrospectively analyzed. The bone cement distribution on the postoperative radiograph was divided into 4 types according to the distribution of the FBMEA on the preoperative MRI.
J Biomed Mater Res B Appl Biomater
January 2025
Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, People's Republic of China.
In dental implant surgery, infection is identified as the primary factor contributing to the failure of bone grafts. There is an urgent need to develop bone graft materials possessing antibacterial characteristics to facilitate bone regeneration. Magnesium phosphate bone cement (MPC) is highly desirable for bone regeneration due to its favorable biocompatibility, plasticity, and osteogenic capabilities.
View Article and Find Full Text PDFJ Clin Med
January 2025
Discipline of Physiotherapy, Faculty of Health Sciences, European University Miguel de Cervantes, C del Padre Julio Chevalier 2, 47012 Valladolid, Spain.
: Hip fractures are prevalent among the elderly and impose a significant burden on healthcare systems due to the associated high morbidity and costs. The increasing use of intramedullary nails for hip fracture fixation has inadvertently introduced risks; these implants can alter bone elasticity and create stress concentrations, leading to peri-implant fractures. The aim of this study is to investigate the outcomes of peri-implant hip fractures, evaluate the potential causes of such fractures, determine the type of treatment provided, assess the outcomes of said treatments, and establish possible improvement strategies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!