Introduction: Focal impulse and rotor modulation (FIRM)-guided ablation has had mixed results of published success, and most studies have had a follow-up for a year or less. We aimed to study a consecutive group of patients followed for at least 1.5 years, subgrouped into those with an initial FIRM ablation and those with a previous, failed ablation who now received a FIRM guided one, to evaluate for success in each group and factors that might affect success.

Methods: Of 181 patients, 167 were available for analysis. Group 1 (n = 122) had a first or primary ablation (paroxysmal atrial fibrillation [PAF] 51; persistent atrial fibrillation [PeAF] 71) and group 2 (n = 45) had a redo ablation (PAF 18; PeAF 27). All patients were done under general anesthesia. FIRM mapping was done in the right atrium first and then the left, and only rotors consistently seen on multiple epochs were ablated, using 15 to 30 W. Rotor ablation was discontinued when remapping showed elimination of rotational activity at the site. Wide area catheter ablation was done for pulmonary vein isolation (PVI). Routine follow-up was at 3, 6, and 12 months of the first year, with a Holter monitor at 6 months, and then every 6 months thereafter. Event recorders were given to patients with potential arrhythmic symptoms.

Results: Mean follow-up was 16 months. Nearly 40% of patients had obstructive sleep apnea; mean body mass index was 32; and average left atrial size was 39.7 mm and 46.2 mm for PAF and PeAF patients, respectively. Freedom from atrial arrhythmia recurrence was: in group 1 patients, 82.4% for PAF and 67.6% for PeAF patients; in group 2 patients, 83.3% for PAF, but only 40.7% for PeAF patients. Comparing outcomes for the first 10 patients studied to the next 20 or more done by three operators showed no difference, suggesting no learning curve affecting the ablation results. Furthermore, the univariate analysis did not show any demographic factor to have an independent significance for ablation success or failure. Spontaneous termination during rotor ablation occurred in 76.8% of PAF and 27.6% of PeAF patients but did not affect the long-term outcomes for maintenance of sinus rhythm.

Conclusions: FIRM-guided atrial ablation plus PVI in our patient population resulted in good success from a recurrence of atrial arrhythmias in patients undergoing an initial ablation procedure. For those with persistent AF undergoing a second procedure now using FIRM guidance plus PVI, the results are lower. Further research is needed to define better the appropriate population for FIRM-guided ablation and the degree of ablation needed for success in these patients.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.13832DOI Listing

Publication Analysis

Top Keywords

peaf patients
20
ablation
14
patients
14
atrial fibrillation
12
group patients
12
persistent atrial
8
firm-guided ablation
8
paf peaf
8
rotor ablation
8
follow-up months
8

Similar Publications

Background: Sodium-glucose cotransporter 2 inhibitors (SGLT2is) reportedly decreased the new-onset atrial arrhythmias in patients with type-2 diabetes (T2DM) or heart failure (HF). This study examined the impact of SGLT2is on catheter ablation for atrial fibrillation (AF) in HF patients without T2DM.

Methods: Persistent AF (PeAF) and HF (N-terminal prohormone of brain natriuretic peptide, NT-proBNP ≥400 pg/ml) patients without T2DM undergoing catheter ablation were prospectively enrolled (n = 102).

View Article and Find Full Text PDF

Background: Numerous studies have demonstrated the significance of trimethylamine-N-oxide (TMAO) in the progression of atrial fibrillation (AF). However, the association between TMAO and AF recurrence (RAF) post-catheter ablation is not yet fully understood. This study aims to elucidate the predictive capability of pre-procedural TMAO levels in determining RAF following catheter ablation (CA).

View Article and Find Full Text PDF

Introduction: Pulmonary vein isolation (PVI) by cryoballoon ablation (CBA) is considered an effective primary strategy for early persistent atrial fibrillation (AF). However, data regarding CBA for long-standing persistent AF (PeAF) are limited. We evaluated the efficacy and safety of CBA for long-standing PeAF compared to PeAF.

View Article and Find Full Text PDF

Using Machine Learning to Predict the Duration of Atrial Fibrillation: Model Development and Validation.

JMIR Med Inform

November 2024

Department of Cardiac Arrhythmia Research and Innovation, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.

Article Synopsis
  • Atrial fibrillation (AF) is categorized by duration into paroxysmal, persistent, and long-standing persistent types, with longer durations increasing the risk of recurrence during catheter ablation treatment.
  • The study aims to enhance the diagnosis accuracy of AF duration through a predictive model, utilizing data from 272 patients to train a machine learning algorithm.
  • Results showed the model achieved 81.8% accuracy in predicting AF duration, significantly improving cardiologists' diagnostic performance from 63.9% to 71.6% after using the model's insights.
View Article and Find Full Text PDF

Aim: To explore the safety and efficacy of a novel strategy (bi-atrial linear catheter ablation guided by electrophysiological mapping) for persistent atrial fibrillation (PeAF) treatment.

Methods: 83 patients with PeAF were enrolled for evaluation of ablation strategy. 43 patients were subjected to pulmonary vein isolation (PVI) strategy (PVI group).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!