Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The assessment of potential cytotoxicity or genotoxicity of combustible tobacco products has historically been performed using partitioned exposures (i.e. total particulate matter [TPM], gas vapor phase [GVP]) rather than whole smoke. The VITROCELL® VC10® smoke exposure system offers multiple platforms for air liquid interface (ALI) or air agar interface (AAI) exposure to mimic in vivo-like conditions for assessing the toxicological impact of whole smoke using in vitro assays (e.g. cytotoxicity, mutagenicity and DNA modifications). The aims of this study were to investigate dosimetry during whole smoke exposure in the VITROCELL® VC10® smoking robot using quartz crystal microbalances (QCMs) and to support the use of photometers for concurrent assessment of 'dose' during whole smoke exposures. QCM results showed consistent deposition across different exposure chambers, between dilution bars, experiments and modules. Higher levels of variation were noted at higher airflows (i.e., >8 L/min). Dosimetry assessed using photometers also showed a high level of consistency between experiments, with no notable impact on deposition on the QCM when the photometers were placed 'in-line' between the dilution bar and the exposure module. However, the use of photometers alone may be not be sufficient to estimate deposition; the predictability of the data-generated equation was poor. Further development of dosimetry methodology and information for use in validated in vitro biological test methods is needed to facilitate on-going aerosol-based research and relative assessment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.tiv.2018.12.010 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!