Purpose: Passive leg raise (PLR), in combination with technologies capable of capturing stroke volume changes, has been widely adopted in the management of shock. However, dedicated evaluation of safety, feasibility, and receptiveness of patients and nursing staff to PLR maneuver is missing.
Methods: A noninterventional, prospective trial recruited adult patients with onset of undifferentiated shock within 24 hours with persistent vasopressor requirements despite fluid resuscitation. A standardized PLR maneuver was used to compare two noninvasive hemodynamic monitoring systems, each without significant impact on the performance of the maneuver. Safety and efficacy of the PLR were evaluated via subjective and objective measures. Objective measures of patient comfort and tolerance were evaluated through changes in vital signs, sedation, and analgesia requirements. Nurses and awake patients completed surveys on their experience.
Results: Seventy-nine patients were enrolled. Testing was aborted in 2 cases for medical reasons (one patient developed rapid atrial fibrillation, second had profound desaturation). Of all, 5.4% of patients required additional vasopressor support after completion of the PLR maneuver due to persistent hypotension and 4.1% of patients required additional sedation. Among awake patients (N = 35), 6% reported pain and 29% reported discomfort. A total of 11% of nurses reported minor technical difficulties with the maneuver.
Conclusion: Passive leg raise maneuver leads to a few serious but reversible complications in a selected population of hemodynamically unstable patients. Although it provides relevant diagnostic information, it may impact patient care. Treating physician should be aware of infrequent but possible complications and appreciate the impact of the maneuver on patients' comfort and nursing workload.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8896338 | PMC |
http://dx.doi.org/10.1177/0885066618820492 | DOI Listing |
Intensive Care Med Exp
January 2025
Davita Tratamento Renal, Rio de Janeiro, Brazil.
Biomimetics (Basel)
December 2024
School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China.
Multirotor drones are widely used in fields such as environmental monitoring, agricultural inspection, and package delivery, but they still face numerous challenges in durability and aerial operation capabilities. To address these issues, this paper presents a biomimetic leg-claw mechanism (LCM) inspired by the biomechanics of birds. The claw of the LCM adopts a bistable gripper design that can rapidly close through external impact or actively close via the coordination of internal mechanisms.
View Article and Find Full Text PDFOper Orthop Traumatol
January 2025
Klinik für Orthopädie und Unfallchirurgie, Martin-Luther-Krankenhaus Berlin, Caspar-Theyss-Str. 27-33, 14193, Berlin, Deutschland.
Objective: Lengthening of the patellar tendon to normalize patellar height and improve knee flexion deficits.
Indications: Flexion deficits in combination with patella baja (Caton index < 0.6).
J Funct Morphol Kinesiol
January 2025
Institute of Human Movement Science, Sport and Health, University of Graz, 8010 Graz, Austria.
: Increasing exercise intensity and performance output with superimposed vibration gains interest, especially in high-performance training. However, the additional benefit of vibration in passive stretching exercises and its mechanisms remain unclarified. : Passive stretching with (ST+V) and without (ST) vibration (20 Hz) was performed in male Olympic youth skiing athletes ( = 8, age: 17.
View Article and Find Full Text PDFJ Physiol Sci
January 2025
Department of Biomedical Engineering, Toyo University, Kawagoe, Japan.
The purpose of this study was to clarify sex differences in the inhibition of sympathetic vasomotor outflow which is caused by the loading of cardiopulmonary baroreceptors. Ten young males and ten age-matched females participated. The participants underwent a passive leg raising (PLR) test wherein they were positioned supine (baseline, 0º), and their lower limbs were lifted passively at 10º, 20º, 30º, and 40º.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!