Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background There are limited data on the role of temporary mechanical circulatory support ( MCS ) devices for cardiogenic shock before left ventricular assist device ( LVAD ) surgery. This study sought to evaluate the trends of use and outcomes of MCS in cardiogenic shock before LVAD surgery. Methods and Results This was a retrospective cohort study from 2005 to 2014 using the National Inpatient Sample (20% stratified sample of US hospitals). This study identified admissions undergoing LVAD surgery with preoperative cardiogenic shock. Admissions for other cardiac surgery and heart transplant were excluded. Temporary MCS was identified using administrative codes. The primary outcome was hospital mortality and secondary outcomes were hospital costs and lengths of stay in admissions with and without MCS use. In this 10-year period, 9753 admissions were identified with 40.6% requiring pre- LVAD MCS . There was a temporal increase in the frequency of cardiogenic shock associated with an increase in non-intra-aortic balloon pump MCS devices. The cohort receiving MCS had greater in-hospital myocardial infarction, ventricular arrhythmias, and use of coronary angiography. On multivariable analysis, older age, myocardial infarction, and need for MCS devices were independently predictive of higher in-hospital mortality. In 696 propensity-matched pairs, use of MCS was predictive of higher in-hospital mortality (odds ratio 1.4 [95% confidence interval 1.1-1.6]; P=0.02) and higher hospital costs, but similar lengths of stay. Conclusions In patients with cardiogenic shock bridged to LVAD therapy, there was a steady increase in preoperative MCS use. Use of MCS identified patients at higher risk for in-hospital mortality and greater resource utilization.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6404446 | PMC |
http://dx.doi.org/10.1161/JAHA.118.010193 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!