Background: Particulate matter (PM) air pollution has been associated with decreased pulmonary function, but the exposure–response relationship in chronic obstructive pulmonary disease (COPD) patients is uncertain, and most studies have only focused on exposures to ambient pollution.

Objectives: We aimed to assess associations between pulmonary function and indoor and ambient PM [Formula: see text] ([Formula: see text]) and black carbon (BC).

Methods: Between November 2012 and December 2014, 125 patients with COPD (mean age, 73.4 y) who were not currently smoking and without known indoor BC sources were recruited. Indoor BC and [Formula: see text] were measured in each home for a week in each season, up to four times a year, followed by in-person spirometry pre- and post-bronchodilator. Ambient exposures were available from a central site monitor. Multivariable adjusted mixed effects regression models were used to assess associations scaled per interquartile range (IQR) of exposure.

Results: There were 367 study visits; the median (IQR) indoor BC and [Formula: see text] were 0.19 (0.22) [Formula: see text] and 6.67 (5.80) [Formula: see text], respectively. Increasing indoor exposures to BC were associated with decreases in pre-bronchodilator forced expiratory volume in 1 s [Formula: see text] and forced vital capacity (FVC), and [Formula: see text]. For example, in multivariable adjusted models, each IQR increase in indoor BC from the weekly integrated filter was associated with a [Formula: see text] [95% confidence interval (CI): [Formula: see text], [Formula: see text]] decrease in pre-bronchodilator [Formula: see text]. Increases in indoor [Formula: see text] were associated with decreases in [Formula: see text] and FVC of smaller magnitude than those for indoor BC; however, the results were less precise. Ambient BC was not associated with pre-bronchodilator pulmonary function, ambient [Formula: see text] was only associated with decreases in FVC and increases in [Formula: see text], and neither indoor nor ambient BC or [Formula: see text] were associated with post-bronchodilator pulmonary function.

Conclusions: Low-level exposures to indoor BC and [Formula: see text], but not ambient exposures, were consistently associated with decreases in pre-bronchodilator pulmonary function. There was no association between exposures and post-bronchodilator pulmonary function. https://doi.org/10.1289/EHP3668.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6371657PMC
http://dx.doi.org/10.1289/EHP3668DOI Listing

Publication Analysis

Top Keywords

[formula text]
72
pulmonary function
24
[formula
19
text]
18
indoor [formula
16
associated decreases
16
indoor ambient
12
ambient [formula
12
text] associated
12
indoor
10

Similar Publications

Dissolution of CO in water followed by the subsequent hydrolysis reactions is of great importance to the global carbon cycle, and carbon capture and storage. Despite numerous previous studies, the reactions are still not fully understood at the atomistic scale. Here, we combined ab initio molecular dynamics (AIMD) simulations with Markov state models to elucidate the reaction mechanisms and kinetics of CO in supercritical water both in the bulk and nanoconfined states.

View Article and Find Full Text PDF

The false evidence rate: An approach to frequentist error rate control conditioning on the observed value.

Proc Natl Acad Sci U S A

January 2025

Centre for Human Genetics, Nuffield Department of Medicine, University of Oxford, Oxford OX3 7BN, United Kingdom.

A value is conventionally interpreted either as a) the probability by chance of obtaining more extreme results than those observed or b) a tool for declaring significance at a prespecified level. Both approaches carry difficulties: b) does not allow users to make inferences based on the data in hand, and is not rigorously followed by researchers in practice, while (a) is not meaningful as an error rate. Although values retain an important role, these shortcomings are likely to have contributed significantly to the scientific reproducibility crisis.

View Article and Find Full Text PDF

The use of winglet devices is an efficient technique for enhancing aerodynamic performance. This study investigates the effects of winglet cant angles on both the aerodynamics and aeroacoustics of a commercial wing, comparing them to other significant parameters using a parametric analysis. A Full Factorial Design method is employed to generate a matrix of experiments, facilitating a detailed exploration of flow physics, with lift-to-drag ratio (L/D) and the integral of Acoustic Power Level (APL) as the primary representatives of aerodynamic and acoustic performance, respectively.

View Article and Find Full Text PDF

Among expanding discoveries of quantum phases in moiré superlattices, correlated insulators stand out as both the most stable and most commonly observed. Despite the central importance of these states in moiré physics, little is known about their underlying nature. Here, we use pump-probe spectroscopy to show distinct time-domain signatures of correlated insulators at fillings of one (ν = -1) and two (ν = -2) holes per moiré unit cell in the angle-aligned WSe/WS system.

View Article and Find Full Text PDF

Self-organized contact line instabilities (CLI) of a macroscopic liquid crystal (LC) droplet can be an ingenious pathway to generate a large collection of miniaturized LC drops. For example, when a larger drop of volatile solvent (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!