The direct oral anticoagulants (DOACs) currently require no monitoring for routine therapy of atrial fibrillation or venous thromboembolism. Measurement of activity, however, may be important in patients with major and life-threatening bleeding, patients needing emergent surgery, in reversal situations, or in patients at high risk of bleeding or thrombosis due to underlying conditions. For these patients, a widely available and rapid turnaround assay would be optimal. To date, there is no such assay available, especially for the direct factor Xa inhibitors. This report describes the performance of a new, rapid turnaround, point-of-care (PoC) assay for measuring the activity of a range of anticoagulants, including DOACs and heparins, in emergency situations and for routine measurement in high-risk patients. Perosphere Technologies' PoC coagulometer is a handheld instrument that performs individual coagulation tests on samples of fresh whole blood (∼10 µL) with clotting activated by glass contact and endpoint determination performed by infrared spectroscopy. In preclinical studies using rats anticoagulated with therapeutic doses of edoxaban or enoxaparin, the PoC coagulometer showed a strong linear correlation between pharmacokinetic parameters and clotting time with edoxaban (  = 0.994) and with enoxaparin (  = 0.967). These preclinical results suggest that this PoC coagulometer would be ideal to assess the pharmacodynamic effects of anticoagulants and their reversal agents. The PoC bedside instrument delivers results within minutes and requires no more than a drop of whole blood. Studies are underway to confirm these results in humans and to further characterize the performance of the instrument.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0038-1676317DOI Listing

Publication Analysis

Top Keywords

poc coagulometer
12
direct oral
8
oral anticoagulants
8
rapid turnaround
8
patients
5
poc
5
novel blood
4
blood point-of-care
4
coagulometer
4
point-of-care coagulometer
4

Similar Publications

Role of Electrode Configuration and Morphology in Printed Prothrombin Time Sensors.

Sens Actuators B Chem

January 2024

Department of Electrical and Computer Engineering, Duke University, Durham NC 27708, USA.

Article Synopsis
  • Patients on long-term anticoagulation therapy need regular PT/INR testing, and while at-home point-of-care (POC) tests could reduce clinic visits, finding a reliable and affordable option has been difficult.
  • Recent advances in printed PT sensors offer potential solutions to cost issues, but have struggled with quality control.
  • This study introduces on-chip redundancy in printed sensors using a small blood sample, analyzing different electrode materials, and finds that silver nanoparticles provide optimal performance for improved functionality in PT testing.
View Article and Find Full Text PDF

Accuracy and Precision of Point-of-Care International Normalized Ratio in Patients With Liver Disease.

J Pediatr Gastroenterol Nutr

June 2023

the Division of Pediatric Gastroenterology and Nutrition, Department of Pediatrics, Edmonton Clinic Health Academy (ECHA), Edmonton, Alberta, Canada.

Objective: To determine if the CoaguChek XS Pro Point-of-Care (POC) device can accurately and precisely measure the international normalized ratio (INR) compared with the gold standard laboratory INR in pediatric and adult patients with liver disease.

Methods: This prospective cohort study included 15 pediatric patients without liver disease, 13 pediatric patients with liver disease, and 17 adult patients with liver disease. The accuracy of the POC INR values was determined using the correlation and Bland-Altman limits of agreement.

View Article and Find Full Text PDF

This review provides a comprehensive and up-to-date overview of point-of-care (POC) devices most commonly used for coagulation analyses in the acute settings. Fast and reliable assessment of hemostasis is essential for the management of trauma and other bleeding patients. Routine coagulation assays are not designed to visualize the process of clot formation, and their results are obtained only after 30-90 m due to the requirements of sample preparation and the analytical process.

View Article and Find Full Text PDF

Background: The use of point-of-care (POC) coagulometers for monitoring patients on vitamin K antagonist (VKA) treatment makes international normalised ratio (INR) results immediately available. The aim of this study was to compare patients' satisfaction with VKA treatment in two settings characterised by distinct ways of monitoring: POC INR versus laboratory INR.

Materials And Methods: We recruited adult patients on long-term warfarin treatment (July 2017-February 2018) from the Anticoagulation Clinics at five district health centres (namely Cospicua, Floriana, Mosta, Qormi, Rabat-POC INR) and at Mater Dei Hospital (Msida - Laboratory INR) in Malta.

View Article and Find Full Text PDF

[Comparison of point of care capillary international normalized ratio (INR) with INR measured in venous samples].

Rev Med Chil

October 2019

Departamento de Oncología Básico-Clínica, Facultad de Medicina, Universidad de Chile, Santiago, Chile.

Background: INR is used to monitor the treatment with vitamin K antagonists. A strategy to reduce waiting times for sampling is to measure INR in a capillary sample using a portable point of care (POC) type coagulometer.

Aim: To evaluate the correlation of CoaguChek Pro II™, Xprecia™ and microINR™ with venous INR measured at the clinical laboratory and their ease of use.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!