Introduction: Peroneal tendon disorders pose a diagnostic conundrum to the clinician. Magnetic resonance imaging (MRI) is widely used to assess tendon pathology. A recognized artifact of MRI, the magic angle effect (MAE), can lead to spurious results and inappropriate management. The aim of this study is to assess whether T2 fat-suppressed sequences (T2FSs) reduce the frequency of MAE compared with proton density fat-suppressed (PDFS) images.

Methods: MRI scans of 18 patients were prospectively assessed for MAE. The peroneal tendons were assessed at 5 defined levels on PDFS and T2FS images. The frequency of MAE in the peroneal tendons were compared between the 2 scan sequences.

Results: In the peroneus brevis tendon, 17/72 levels, on PDFS scans, showed MAE compared with 2/72 levels on the T2FS scans, demonstrating a reduction in the MAE by 85% (P = .0003). In the peroneus longus tendon 14/72 levels, on PDFS scans, demonstrated MAE compared with 4/72 on T2FSs, demonstrating a reduction of 71% (P = .02).

Conclusion: The inclusion of T2-weighted sequences is useful in MRI scanning for peroneal tendons to mitigate the MAE artifact, avoid potential misdiagnosis, and guide subsequent management of peroneal tendon disorders. Level IV: Case series.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1938640018819783DOI Listing

Publication Analysis

Top Keywords

peroneal tendons
16
mae compared
12
levels pdfs
12
magic angle
8
peroneal tendon
8
tendon disorders
8
mae
8
frequency mae
8
mae peroneal
8
pdfs scans
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!