Objective: The ultimate goal of this study is to reassess the five-dimensional implantation markers and pregnancy predictors on the day of human chorionic gonadotropin injection in the intracytoplasmic sperm injection and embryo transfer programs.
Design: A pilot prospective clinical trial.
Setting: The Assisted Reproductive Technology Unit of Ain Shams Maternity Teaching Hospital during the period from April 2014 to December 2017.
Patients And Methods: The study was conducted on 400 women undergoing intracytoplasmic sperm injection (ICSI). Those women were not older than 40 years, with normal uterine cavity and with no previous uterine scars.
Intervention: The ovarian stimulation protocol, used in this study for all patients, was the long protocol, before ovarian stimulation therapy, patients were instructed to use oral contraceptive pills from day 2 starting in the preceding cycle, then the standard regimen. On the day of hCG administration, 5D transvaginal ultrasound measurements were performed by the same observer after the patients had emptied their bladders. Measurements included endometrial volume and 3D power Doppler parameters, endometrial vascularization index, flow index, and vascularization flow index.
Results: The present study shows that endometrial volume ≥ 5 in the prediction of endometrial receptivity in ICSI patients had good sensitivity and low specificity in a group application; in an individual application it had good predictive negative value and bad predictive positive value. So it could be used as a good test to exclude success. Overall pregnancy rate was 40.5%; endometrial volume, flow index, vascularization index, and vascularization flow index were significantly lower in the nonpregnant group than those of the pregnant group. The area under curve in the receiver operating characteristic for three-dimensional ultrasound and power Doppler angiography parameters was statistically significant, but their values were suggestive but not conclusive in the prediction of endometrial receptivity in ICSI patients, no cutoff points with good diagnostic characteristics could be obtained.
Conclusion: Five-dimensional ultrasound and power Doppler angiography is a useful exam to assess the endometrial receptivity in IVF/ICSI and embryo transfer cycles.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00404-018-5001-4 | DOI Listing |
Placenta
December 2024
Department of Obstetrics and Gynecology, Erasmus MC, University Medical Center, Rotterdam, the Netherlands. Electronic address:
Background: Maternal obesity is associated with maternal complications, including hypertensive disorders of pregnancy (HDP), and related fetal complications, such as fetal growth restriction. During pregnancy, the placenta is one of the key regulators of embryonic and fetal growth. Previous studies mainly investigated placental growth by measuring postpartum placental weight.
View Article and Find Full Text PDFClin Rheumatol
January 2025
Department of Rheumatology, Huashan Hospital, Fudan University, No.12 Wulumuqi Zhong Road, Shanghai, 200040, China.
To evaluate the association of anti-IFI16 antibodies with peripheral vasculopathy and the predictive value of anti-IFI16 antibodies for the development or persistence of digital ulcers (DPDU) in SSc. A total of 42 SSc patients and 42 age- and sex-matched healthy controls were enrolled. Anti-IFI16 antibodies were examined by ELISA.
View Article and Find Full Text PDFCirc Cardiovasc Imaging
January 2025
Department of Cardiology, Odense University Hospital, Denmark (N.S.B.M., J.S.D., M.A., A.H., R.C.-S., J.E.M., K.A.Ø., M.-A.C.).
Background: Aortic valve calcification (AVC) has been shown to be a powerful assessment of aortic stenosis (AS) severity and a predictor of adverse outcomes. However, its accuracy in patients with low-flow AS has not yet been proven. The objective of the study was to assess the predictive value of AVC in patients with classical low-flow (CLF, that is, low-flow reduced left ventricular ejection fraction) or paradoxical low-flow (PLF, that is, low-flow preserved left ventricular ejection fraction) AS.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Electrical, Computer and Biomedical Engineering, Toronto Metropolitan University, Toronto, ON M5B2K3, Canada.
Unmanned aerial vehicle (UAV)-enabled vehicular communications in the sixth generation (6G) are characterized by line-of-sight (LoS) and dynamically varying channel conditions. However, the presence of obstacles in the LoS path leads to shadowed fading environments. In UAV-assisted cellular vehicle-to-everything (C-V2X) communication, vehicle and UAV mobility and shadowing adversely impact latency and throughput.
View Article and Find Full Text PDFFront Med (Lausanne)
December 2024
Rheumatology Department, Unidade Local de Saúde de Santa Maria, Lisbon, Portugal.
Objective: The study aimed to explore the utility of contrast-enhanced ultrasound (CEUS) as a tool for detecting minimal inflammation in rheumatoid arthritis (RA) patients in sustained remission (SR) and to correlate the findings with Disease Activity Score 28 (DAS28) status scores and various ultrasound (US) scores.
Patients And Methods: Thirty RA patients in SR (minimum 6 months), 12 with active disease, and 10 healthy controls were included. Clinical evaluations and US assessments were performed, including grayscale US (GSUS), power Doppler US (PDUS), and Global OMERACT-EULAR Synovitis Score (GLOESS).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!