A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Percutaneous closure of perimembranous ventricular septal defects utilizing almost ideal Amplatzer Duct Occluder II: Why limitation in sizes? | LitMetric

Aim: The purpose of this study is to describe the special aspects of perimembranous ventricular septal defects (pmVSD) closure by utilizing Amplatzer Duct Occluder II (ADO II) devices with a rational request for bigger ADO-II sizes, based on our experience in transcatheter device closure of pmVSD.

Methods And Results: At our institution, placement of an ADO II device was used in 15 patients with pmVSD; the patients' age ranged between 6 months and 20 years. The indications for closure were CHF (n = 4), hemodynamically significant shunt (n = 7), tricuspid regurgitation (n = 3), and high risk for infective endocarditis (n = 2), respectively. The location of the VSD was infracristal in 13 patients, supracristal in 1, and a postsurgical Gerbode VSD in another one. Implantation of the device was successfully performed without embolization, any evidence of an AV block, or other conductance abnormalities during implantation and follow-up in the mean of 2.5 years (range 2 months-6.5 years).

Conclusions: Transcatheter closure of a pmVSD with ADO II is feasible in all pediatric and young adult age groups, by considering the device diameter limitations. The off-label use of ADO II implantation seems to be safe for VSDs closure up to 6 mm of size and feasible for various locations including unusual morphology such as postsurgical Gerbode defect.

Download full-text PDF

Source
http://dx.doi.org/10.1111/chd.12731DOI Listing

Publication Analysis

Top Keywords

perimembranous ventricular
8
ventricular septal
8
septal defects
8
amplatzer duct
8
duct occluder
8
postsurgical gerbode
8
closure
5
percutaneous closure
4
closure perimembranous
4
defects utilizing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!