The changes of particles and organic pollutants in indoor atmospheres as consequence of vaping with electronic cigarettes have been analyzed. Changes in the composition of volatile organic compounds (VOCs) in exhaled breath of non-smoking volunteers present in the vaping environments have also been studied. The exposure experiments involved non-vaping (n = 5) and vaping (n = 5) volunteers staying 12 h together in a room (54 m) without external ventilation. The same experiment was repeated without vaping for comparison. Changes in the distributions of particles in the 8-400 nm range were observed, involving losses of nucleation-mode particles (below 20 nm) and increases of coagulation processes leading to larger size particles. In quantitative terms, vaping involved doubling the indoor concentrations of particles smaller than 10 μm, 5 μm, and 1 μm observed during no vaping. The increase of particle mass concentrations was probably produced from bulk ingredients of the e-liquid exhaled by the e-cigarette users. Black carbon concentrations in the indoor and outdoor air were similar in the presence and absence of electronic cigarette emissions. Changes in the qualitative composition of PAHs were observed when comparing vaping and non-vaping days. The nicotine concentrations were examined separately in the gas and in the particulate phases showing that most of the differences between both days were recorded in the former. The particulate phase should therefore be included in nicotine monitoring during vaping (and smoking). The concentration increases of nicotine and formaldehyde were small when compared with those described in other studies of indoor atmospheres or health regulatory thresholds. No significant changes were observed when comparing the concentrations of exhaled breath in vaping and no vaping days. Even the exhaled breath nicotine concentrations in both conditions were similar. As expected, toluene, xylenes, benzene, ethylbenzene, and naphthalene did not show increases in the vaping days since combustion was not involved.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-018-3975-xDOI Listing

Publication Analysis

Top Keywords

exhaled breath
16
vaping
12
electronic cigarette
8
organic pollutants
8
indoor atmospheres
8
observed comparing
8
nicotine concentrations
8
vaping days
8
particles
6
concentrations
6

Similar Publications

Ischemic heart disease (IHD) impacts the quality of life and is the most frequently reported cause of morbidity and mortality globally. To assess the changes in the exhaled volatile organic compounds (VOCs) in patients with vs. without ischemic heart disease (IHD) confirmed by stress computed tomography myocardial perfusion (CTP) imaging.

View Article and Find Full Text PDF

Bacterial infection of the lower respiratory tract frequently occurs in mechanically ventilated patients and may develop into life-threatening conditions. Yet, existing diagnostic methods have moderate sensitivity and specificity, which results in the overuse of broad-spectrum antibiotics administered prophylactically. This study aims to evaluate the suitability of volatile bacterial metabolites for the breath-based test, which is used for diagnosing Ventilator-Associated Pneumonia (VAP).

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the fractional exhaled nitric oxide (FeNO) levels in a healthy population to better understand normal ranges and their influencing factors.
  • FeNO levels were measured in 2,251 participants aged 6-82 years, revealing median values that increase with age and vary based on gender, height, and eosinophil counts.
  • The findings establish reference ranges for FeNO that can aid in clinical asthma diagnosis and management.
View Article and Find Full Text PDF
Article Synopsis
  • The gold standard for measuring aerobic capacity in athletes is the VO2-max test, but it doesn't provide insights into muscular metabolic changes.
  • Near-infrared spectroscopy (NIRS) is a new technology that measures local oxygen levels in tissues, helping assess both breathing costs and muscle workload during exercise.
  • By analyzing changes in oxygen levels and tissue saturation, coaches and exercise physiologists can identify limitations in endurance training, improving athletic performance through tailored strategies.
View Article and Find Full Text PDF

Online monitoring of propofol concentrations in exhaled breath.

Heliyon

December 2024

Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.

Propofol, a widely used intravenous anesthetic agent, requires accurate monitoring to ensure therapeutic efficacy and prevent oversedation. Recent developments in modern analytical instrumentation have led to significant breakthroughs in on-line analysis of exhaled breath. This review discusses several sophisticated analytical methods that have been explored for noninvasive, real-time monitoring of propofol concentrations, including proton transfer reaction mass spectrometry, selected ion flow tube mass spectrometry, ion mobility spectrometry, and gas chromatography coupled to surface acoustic wave sensors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!