Given that the peculiar redox behavior of ergothioneine involves a rapid regeneration process, the measurement of its precursor and redox metabolite hercynine could be particularly useful in assessing its role in oxidative stress or other biological processes. Thus, a LC-MS/MS method for the determination of hercynine concentrations in whole blood was developed. After lysis of red blood cells by cold water, samples were filtered on micro concentrators at a controlled temperature of 4 °C. The clear filtered fluid was then treated with diethylpyrocarbonate to derivatize hercynine for the analysis by LC-MS/MS. The derivatized analyte was isocratically separated as a carbethoxy derivative on a C18 column with a mobile phase of an aqueous 0.1% / formic acid and acetonitrile (95:5). Effluents were monitored by MRM transitions at / 270.28→95 and 273.21→95 for hercynine and its deuterated counterpart, respectively. No cross-talk between MRM transitions was observed and a good linearity was found within a range of 35⁻1120 nmol/L. The LOD and LOQ were, respectively, 10.30 and 31.21 nmol/L with an intraday and intermediate precision below 7%. The average hercynine concentration in whole blood from 30 healthy male volunteers (aged 77 ± 12 years) was 178.5 ± 118.1 nmol/L. Overall, the method is easy to perform, allowing a rapid and accurate assessment of whole blood concentrations of hercynine.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6321398 | PMC |
http://dx.doi.org/10.3390/molecules23123326 | DOI Listing |
Metabolites
January 2025
Segal Cancer Proteomics Centre, Lady Davis Institute for Medical Research, Jewish General Hospital, McGill University, Montreal, QC H3T 1E2, Canada.
Quantifying urinary catecholamines and metanephrines is essential for the clinical screening and diagnosis of neuroendocrine tumours. HPLC with electrochemical detection (HPLC-ECD) is commonly used for this type of analysis but requires extensive sample cleanup. Simple and rapid dilute-and-shoot LC-multiple-reaction monitoring (MRM)-MS assays have been developed for quantitating these analytes in urine but have not yet been validated according to the Clinical and Laboratory Standards Institute (CLSI) guidelines.
View Article and Find Full Text PDFFood Res Int
February 2025
New Hazardous Substances Division, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Osong, Cheongju, Chungcheongbuk-do 28159, Republic of Korea. Electronic address:
Authentication of gelatin sources are required for cultural beliefs and food integrity. This paper describes a sensitive and rapid detection of gelatin sources using liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. The specific peptide markers were adopted to accurately identify bovine and porcine gelatin in pharmaceutical capsules and jellies.
View Article and Find Full Text PDFRSC Adv
January 2025
Department of Chemistry, School of Science, GITAM Deemed to be University Hyderabad-502329 India
The current research presents novel LC-TQ-MS/MS and cost-effective UPLC methods intended for the accurate quantification of mefenamic acid-N-nitroso drug substance-related impurity-NDSRI (N-MFA) in mefenamic acid (MFA) tablet and pediatric suspension dosage forms. The acceptable intake of N-MFA is derived from the TD50 (Median Toxic Dose-50%) value of N-nitroso diphenylamine. The analytical separation was achieved for the UPLC method using an XBridge BEH Shield RP18 Column (150 × 3.
View Article and Find Full Text PDFDrug Des Devel Ther
January 2025
The First Affiliated Hospital of Wenzhou Medical University, Zhejiang, People's Republic of China.
Background: Givinostat, a potent histone deacetylase (HDAC) inhibitor, is promising for the treatment of relapsed leukemia and myeloma.
Purpose: This study aimed to develop and verify a quick assay for the measurement of givinostat concentration using ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) with eliglustat as the internal standard (IS), establishing a basic pharmacokinetic profile for its pre-clinical application and metabolic stability in vitro.
Methods: Sample preparation was performed via protein precipitation using acetonitrile.
J Chromatogr B Analyt Technol Biomed Life Sci
January 2025
Anhui Provincial Center of Drug Clinical Evaluation, Yijishan Hospital of Wannan Medical College, Wuhu, Anhui, PR China. Electronic address:
Eldecalcitol is a novel analog of 1α,25-dihydroxyvitamin D [1,25(OH)D] for the treatment of patients with osteoporosis. A highly sensitive and specific ultra-performance liquid chromatography coupled to atmospheric pressure chemical ionization tandem mass spectrometry (UPLC-APCI-MS/MS) technique featuring a lower limit of quantitation (LLOQ) as low as 5 pg/ml, has been established and validated for the rapid and accurate quantification of eldecalcitol in human plasma samples. Plasma samples were extracted by solid phase extraction (SPE).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!