Purpose/objectives: To evaluate the plan quality and treatment delivery efficiency of single-isocenter/two-lesions volumetric modulated arc therapy (VMAT) lung stereotactic body radiation therapy (SBRT).
Materials/methods: Eight consecutive patients with two peripherally located early stage nonsmall-cell-lung cancer (NSCLC) lung lesions underwent single-isocenter highly conformal noncoplanar VMAT SBRT treatment in our institution. A single-isocenter was placed between the two lesions. Doses were 54 or 50 Gy in 3 and 5 fractions respectively. Patients were treated every other day. Plans were calculated in Eclipse with AcurosXB algorithm and normalized to at least 95% of the planning target volume (PTV) receiving 100% of the prescribed dose. For comparison, two-isocenter plans (isocenter placed centrally in each target) were retrospectively created. Conformity indices (CIs), heterogeneity index (HI), gradient index (GI), gradient distance (GD), and D were calculated. The normal lung V5, V10, V20, mean lung dose (MLD) and other organs at risk (OARs) doses were evaluated. Total number of monitor units (MUs), beam-on time, and patient-specific quality assurance (QA) results were recorded.
Results: The mean isocenter to tumor distance was 6.7 ± 2.3 cm. The mean combined PTV was 44.0 ± 23.4 cc. There was no clinically significant difference in CI, HI, GD, GI, D , and V20 including most of the OARs between single-isocenter and two-isocenter lung SBRT plans, evaluated per RTOG guidelines. However, for single-isocenter plans as the distance between the lesions increased, the V5, V10, and MLD increased, marginally. The total number of MUs and beam-on time was reduced by a factor of 1.5 for a single-isocenter plan compared to a two-isocenter plan. The single-isocenter/two-lesions VMAT lung SBRT QA plans demonstrated an accurate dose delivery of 98.1 ± 3.2% for clinical gamma passing rate of 3%/3 mm.
Conclusion: The SBRT treatment of two peripherally located lung lesions with a centrally placed single-isocenter was dosimetrically equivalent to two-isocenter plans. Faster treatment delivery for single-isocenter treatment can improve patient compliance and reduce the amount of intrafraction motion errors for well-suited patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6333146 | PMC |
http://dx.doi.org/10.1002/acm2.12500 | DOI Listing |
Trials
January 2025
London Centre for Primary Care, Wolfson Institute of Population Health, Queen Mary University of London, London, UK.
Background: The aim of the SURECAN trial is to evaluate a person-centred intervention, based on Acceptance and Commitment Therapy (ACT Plus ( +)), for people who have completed treatment for cancer with curative intent, but are experiencing poor quality of life. We present the statistical analysis plan for assessing the effectiveness and cost-effectiveness of the intervention in improving quality of life 1 year post randomisation.
Methods And Design: SURECAN is a multi-centre, pragmatic, two-arm, partially clustered randomised controlled superiority trial comparing the effectiveness of ACT + added to usual care with usual aftercare.
BMC Public Health
January 2025
Division of General Medicine, University of Michigan Medical School, Ann Arbor, USA.
Background: Modeling studies suggest that hundreds of thousands of U.S. children have lost caregivers since the COVID-19 pandemic began.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Department of Orthopedics, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, 215000, China.
Background: To analyze the effects of the positioning of a bolt in the femoral neck system (FNS) on the short-term outcomes of middle-aged and young adults with displaced femoral neck fractures (FNFs).
Methods: This was a retrospective study involving 114 middle-aged and young adults with displaced FNFs who were surgically treated with internal fixation via the FNS in the Department of Orthopedics, Suzhou Municipal Hospital, from December 2019 to January 2023. The degree of deviation of the central axis of the femoral head and neck from the tip of the bolt (W), the tip‒apex distance (TAD) and the length of femoral neck shortening (LFNS) were measured on postoperative X-ray and computed tomography (CT) scan images.
Background: Over the past two decades, the UK has actively developed policies to enhance early cancer diagnosis, particularly for individuals with non-specific cancer symptoms. Non-specific symptom (NSS) pathways were piloted and then implemented in 2015 to address delays in referral and diagnosis. The aim of this study was to outline the functions that enable NSS teams to investigate cancer and other diagnoses for patients with NSSs.
View Article and Find Full Text PDFBMJ Open
January 2025
Centre for Health Services Studies, University of Kent, Canterbury, UK.
Background: Older adult care homes in England are required to develop care plans on behalf of each of their residents and to make these documents available to those who provide care. However, there is a lack of formal agreement around the key principles that should inform the development of care plans in care homes for older adults. Using a modified Delphi survey, we intend to generate consensus on a set of key principles that should inform the care planning process.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!