A compact dual-cavity Fabry-Perot interferometer (DC-FPI) sensor is proposed and demonstrated based on a hollow-core photonic bandgap fiber (HC-PBF) spliced with a hollow-core fiber (HCF). The HC-PBF, which has low transmission loss, was used as the first FPI cavity and also acted as a bridge between the lead-in single-mode fiber and the HCF. The HCF was used as the second FPI cavity and also acted as a micro gas inlet into the first FPI cavity. A DC-FPI sensor with different cavity lengths of 226 and 634 μm in the first FPI and the second FPI was created. Both gas pressures ranging from 0-10 MPa and temperatures ranging from 100-800°C were measured using the DC-FPI sensors together with a fast Fourier transform and phase-demodulation algorithm. Experimental results showed that the first FPI cavity was gas pressure sensitive but temperature insensitive, while the second FPI cavity was temperature sensitive but gas pressure insensitive. A high gas pressure sensitivity of 1.336 μm/MPa and a temperature sensitivity of 17 nm/°C were achieved in the DC-FPI sensor. Moreover, the cross sensitivity between the gas pressure and temperature was calculated to be ∼-15 Pa/°C and ∼0.3°C/MPa. The proposed DC-FPI sensors provide a promising candidate for the simultaneous measurement of high pressures and high temperatures at some precise locations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.43.006009 | DOI Listing |
Sensors (Basel)
November 2024
Hubei Key Laboratory of Optical Information and Pattern Recognition, Wuhan Institute of Technology, Wuhan 430205, China.
An all-fiber vibration sensor based on the Fabry-Perot interferometer (FPI) is proposed and experimentally evaluated in this study. The sensor is fabricated by introducing a Fabry-Perot cavity to the single-mode fiber using femtosecond laser ablation. The cavity and the tail act together as a cantilever beam, which can be used as a vibration receiver.
View Article and Find Full Text PDFIn this paper, we proposed an in-fiber Fabry-Perot temperature sensor which filled with Indium gallium stannum (InGaSn) alloy. By splicing a single-mode fiber axially with hollow-core fibers (HCFs) of varying inner diameters, a cavity of the Fabry-Perot interferometer (FPI) structure is formed. Assisted by liquid metal with fluidity and high thermal expansivity, subtle temperature fluctuations are converted into variations in the interferometric cavity length which leads to a significant spectral drift.
View Article and Find Full Text PDFTalanta
January 2025
Henan Key Laboratory of Laser and Opto-electric Information Technology, School of Electrical and Information Engineering, Zhengzhou University, Zhengzhou, 450001, China. Electronic address:
Detection of volatile organic compounds (VOCs) is crucial in industrial production, environmental monitoring, and public safety. VOCs sensors need to be intrinsically safe, given the flammability and toxicity of common VOCs. Fiber optic sensors offer a passive and flexible solution for VOCs detection, attracting significant attention from researchers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!