The rates of restenosis and stent thrombosis after the therapeutic stent deployment for bifurcation lesions are still comparably high after the introduction of the new-generation drug-eluting stents (DESs), because of the various factors including their morphology. We experienced a case of a successful percutaneous coronary intervention using three-dimensional optical coherence tomography (3D OCT) with a single stent deployment to a bifurcation lesion of the left anterior descending artery (LAD) and left circumflex artery (LCx) with a following kissing-balloon inflation (KBI). The 3D OCT, after the inflation of the jailed ostium of the LCx following the stent deployment to the LAD crossing the LCx, could clearly demonstrate a stent deformation and incomplete apposition at an opposite site of the LCx, which may cause high rates of restenosis and stent thrombosis. These stent abnormalities were steadily corrected by a subsequent KBI of the LAD and LCx. Furthermore, the 3D OCT images were the same findings as those of the experiments from both an phantom coronary bifurcation model and macroscopic images of the stent. < In view of this case report, these modalities with three-dimensional optical coherence tomography and the techniques for the following kissing-balloon inflation may be one of the useful and effective therapeutic strategies to reduce the rates of restenosis and stent thrombosis of the percutaneous coronary intervention for bifurcation lesions.>.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6280694 | PMC |
http://dx.doi.org/10.1016/j.jccase.2015.12.003 | DOI Listing |
Sci Rep
January 2025
Center for Advanced Laser Technologies (CETAL), National Institute for Lasers, Plasma and Radiation Physics, Magurele-Ilfov, 077125, Romania.
Nature offers unique examples that help humans produce artificial systems which mimic specific functions of living organisms and provide solutions to complex technical problems of the modern world. For example, the development of 3D micro-nanostructures that mimic nocturnal insect eyes (optimized for night vision), emerges as promising technology for detection in IR spectral region. Here, we report a proof of principle concerning the design and laser 3D printing of all ultrastructural details of nocturnal moth Grapholita Funebrana eyes, for potential use as microlens arrays for IR detection systems.
View Article and Find Full Text PDFHear Res
January 2025
Columbia University Irving Medical Center, Department of Otolaryngology, Head and Neck Surgery, 180 Fort Washington Ave, New York, 10032, NY, USA; Columbia University, Department of Biomedical Engineering, 1210 Amsterdam Ave, New York, 10027, NY, USA.
Sound-evoked displacement responses at the outer hair cell-Deiters' cell junction (OHC-DC) are of significant interest in cochlear mechanics, as OHCs are believed to be in part responsible for active tuning enhancement and amplification. Motion in the cochlea is three-dimensional, and the architecture of the organ of Corti complex (OCC) suggests the presence and mechanical importance of all three components of motion. Optical coherence tomography (OCT) displacement measurements of OHC-DC motion from different experimental preparations often show disparate results, potentially due to OCT measuring only the motion component along the beam axis.
View Article and Find Full Text PDFJ Biomed Opt
January 2025
The Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.
Significance: Laparoscopic surgery presents challenges in localizing oncological margins due to poor contrast between healthy and malignant tissues. Optical properties can uniquely identify various tissue types and disease states with high sensitivity and specificity, making it a promising tool for surgical guidance. Although spatial frequency domain imaging (SFDI) effectively measures quantitative optical properties, its deployment in laparoscopy is challenging due to the constrained imaging environment.
View Article and Find Full Text PDFNat Commun
January 2025
State Key Laboratory for Extreme Photonics and Instrumentation, International Research Center for Advanced Photonics, Ningbo Innovation Center, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, China.
The frequency-modulated continuous-wave (FMCW) technology combined with optical phased array (OPA) is promising for the all-solid-state light detection and ranging (LiDAR). We propose and experimentally demonstrate a silicon integrated OPA combined with an optical frequency microcomb for parallel LiDAR system. For realizing the parallel wavelengths emission consistent with Rayleigh criterion, the wide waveguide beyond single mode region combined with the bound state in the continuum (BIC) effect is harnessed to obtain an ultra-long optical grating antenna array.
View Article and Find Full Text PDFInorg Chem
January 2025
Department of Chemistry, University of Southern California, Los Angeles, California 90089, United States.
The functional properties of tetraaryl compounds, M(aryl) (M = transition metal or group 14 element), are dictated not only by their common tetrahedral geometry but also by their central atom. The identity of this atom may serve to modulate the reactivity, electrochemical, magnetic, and optical behavior of the molecular species, or of extended materials built from appropriate tetraaryl building blocks, but this has not yet been systematically evaluated. Toward this goal, here we probe the influence of Os(IV), C, and Si central atoms on the spectroelectrochemical properties of a series of redox-active tetra(ferrocenylaryl) complexes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!