A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultrasound point shear wave elastography of the pancreas: comparison of patients with type 1 diabetes and healthy volunteers - results from a pilot study. | LitMetric

Background: The aims of this study were to establish shear wave elastography of the pancreas by comparing measurements in patients with type 1 diabetes (T1D) and healthy volunteers and to consider whether this method could contribute to the screening or prevention of T1D.

Methods: This pilot study included 15 patients with T1D (10 men, 5 women) and 15 healthy volunteers (10 men, 5 women) as controls. Measurements were performed with a Siemens Acuson S3000 (Siemens Healthcare, Erlangen, Germany) using a 6C1 convex transducer and the Virtual Touch™ tissue quantification (VTQ) method.

Results: The mean shear wave velocity of the head of the pancreas was 1.0 ± 0.2 m/s (median: 1.1 m/s) for the study group and likewise 1.0 ± 0.2 m/s (median: 0.9 m/s) for the control group. Velocities of 1.2 ± 0.2 m/s (median: 1.2 m/s) were measured in the body of the pancreas in both groups. There was a significant difference between the values obtained in the tail of the pancreas: patients 1.1 ± 0.1 m/s (median: 1.0 m/s) versus controls 0.9 ± 0.1 m/s (median: 0.8 m/s) (p = 0.0474). The mean value in the whole pancreas of the study group was not significantly above that of the control group: 1.1 ± 0.1 m/s (median: 1.0 m/s) versus 1.0 ± 0.1 m/s (median: 1.0 m/s) (p = 0.2453).

Conclusions: Sonoelastography of the pancreas revealed no overall difference between patients with T1D and healthy volunteers. Patients with T1D showed higher values only in the tail segment. Future studies need to determine whether specific regional differences can be found in a larger study population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6293554PMC
http://dx.doi.org/10.1186/s12880-018-0295-zDOI Listing

Publication Analysis

Top Keywords

healthy volunteers
16
shear wave
12
patients t1d
12
median 10 m/s
12
wave elastography
8
elastography pancreas
8
patients type
8
type diabetes
8
pilot study
8
t1d healthy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!