(1) Background. Titanium is characterized by its biocompatibility, resistance to maximum stress, and fatigue and non-toxicity. The composition, surface structure, and roughness of titanium have a key and direct influence on the osseointegration processes when it is used in the form of dental implants. The objective of the present study is to characterize, at chemical, superficial, and biological levels, the result of the application of the sandblasted with large-grit and acid-etched (SLA) treatment consisting of coarse-grained and double-passivated acid blasting with subsequent decontamination with argon plasma on the surface of titanium implants type IV. (2) Methods. Four Oxtein dental implants (Zaragoza, Spain) were investigated with the following coding: Code L63713T (titanium grade IV, 3.75 mm in diameter, and 13 mm in length). The surface of the implants was SLA type obtained from coarse-grained, double passivated acid, and decontaminated with argon plasma. The samples were in their sealed packages and were opened in our laboratory. The X-ray photoelectron spectroscopy (XPS) technique was used to characterize the chemical composition of the surface, and the scanning electronic microscope (SEM) technique was used to perform topographic surface evaluation. Cell cultures were also performed on both surfaces. (3) Results. The superficial chemical analysis of the studied samples presented the following components, approximately, expressed in atomic percentage: O: 39%; Ti: 18%; C: 39%; N: 2%; and Si: 1%. In the same way, the topographic analysis values were obtained in the evaluated roughness parameters: R: 1.5 μm ± 0.02%; R: 1.31 μm ± 0.33; R: 8.98 μm ± 0.73; R: 5.12 μm ± 0.48; R: 3.76 μm ± 0.51; and R: 4.92 μm ± 0.24. At a biological level, the expression of osteocalcin was higher ( < 0.05) on the micro-rough surface compared to that machined at 48 and 96 h of culture. (4) Conclusions. The data obtained in our study indicate that the total carbon content, the relative concentration of titanium, and the roughness of the treatment performed on the implants are in agreement with those found in the literature. Further, the roughness of the treatment performed on the implants throws a spongy, three-dimensional surface suitable for bone growth on it. The biological results found are compatible with the clinical use of the surface tested.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6306932PMC
http://dx.doi.org/10.3390/jfb9040071DOI Listing

Publication Analysis

Top Keywords

argon plasma
12
surface
9
decontamination argon
8
composition surface
8
dental implants
8
characterize chemical
8
roughness treatment
8
treatment performed
8
performed implants
8
titanium
6

Similar Publications

Modelling the Impact of Argon Atoms on a WO Surface by Molecular Dynamics Simulations.

Molecules

December 2024

Institute of Ion Physics and Applied Physics, University of Innsbruck, Technikerstraße 25, 6020 Innsbruck, Austria.

Machine learning potential energy functions can drive the atomistic dynamics of molecules, clusters, and condensed phases. They are amongst the first examples that showed how quantum mechanics together with machine learning can predict chemical reactions as well as material properties and even lead to new materials. In this work, we study the behaviour of tungsten trioxide (WO) surfaces upon particle impact by employing potential energy surfaces represented by neural networks.

View Article and Find Full Text PDF

Inductively coupled plasma-reactive etching (ICP-RIE) of InGaZnO (IGZO) thin films was studied with variations in gas mixtures of hydrochloride (HCl) and argon (Ar). The dry etching characteristics of the IGZO films were investigated according to radiofrequency bias power, gas mixing ratio, and chamber pressure. The IGZO film showed an excellent etch rate of 83.

View Article and Find Full Text PDF

This paper presents the initial results of the synthesis of β-GaO luminescent ceramics via plasma gas-thermal spraying synthesis, where low-temperature plasma of an argon and nitrogen mixture was employed. A direct current electric arc generator of high-enthalpy plasma jet with a self-aligning arc length and an expanding channel of an output electrode served as a plasma source. The feedstock material consisted of a polydisperse powder of monocrystalline β-GaO with particle sizes ranging from 5 to 50 μm.

View Article and Find Full Text PDF

Background And Aims: Endoscopic mucosal resection (EMR) of large colorectal lesions can be challenging, and residual lesions after EMR can progress to colorectal cancer. We aimed to assess the efficacy and safety of adding thermal ablation of margins [using argon plasma coagulation (APC) or snare tip soft coagulation (STSC)] in reducing recurrence rates after EMR.

Methods: We performed a systematic review and meta-analysis of randomized controlled trials (RCTs) identified from PubMed, Cochrane Library, and Embase.

View Article and Find Full Text PDF
Article Synopsis
  • Endoscopic ablation is the primary treatment for dysplastic Barrett's esophagus (BE), primarily utilizing radiofrequency ablation (RFA) and argon plasma coagulation (APC) in Polish medical centers.
  • A retrospective analysis of 160 adult patients revealed high rates of complete remission for intestinal metaplasia (80.0%) and dysplasia (93.8%), alongside a manageable adverse event rate, with 30.6% reporting minor and 5.6% major complications.
  • The study also identified that RFA, used more for severe cases, had a higher failure rate compared to APC/h-APC, particularly in patients with long-segment BE and diabetes, suggesting specific risk factors for less favorable treatment outcomes
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!