The development of diagnostics for rolling element bearings (REBs) in recent years makes it possible to detect faults in bearings in real-time. Squared envelope analysis (SEA), in which the statistical characteristics of the squared envelope (SE) or the squared envelope spectrum (SES) are analysed, is widely recognized as both an effective and the simplest method. The most critical step of SEA is to find an optimal frequency band that contains the maximum defect information. The most commonly used approaches for selecting the optimal frequency band are derived from measuring the kurtosis of the SE or the SES. However, most methods fail to cope with the interference of a single or a few impulses in the corresponding domain. A new method is proposed in this paper called "PMFSgram", which just calculates the kurtosis of the SES in the range centred at the first two harmonics with a span of three times the modulation frequency rather than the entire SES of the band filtered signals. It is possible to avoid most of the interference from a small number of undesired impulses in the SES. PMFSgram uses several bandwidths from 1.5 times to 4.5 times the fault frequency and for each bandwidth has the same number of central frequencies. The frequency setting method is able to select an optimal frequency band containing most of the useful information with less noise. The performance of the new method is verified using synthesized signals and actual vibration data.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308421 | PMC |
http://dx.doi.org/10.3390/s18124344 | DOI Listing |
Nanophotonics
January 2025
Departments of Optics and General Physics, Francisk Skorina Gomel State University, Sovetskaya Str. 104, Gomel 246019, Belarus.
Optical vortex beams carrying orbit angular momentum have attracted significant attention recently. Perfect vortex beams, characterized by their topological charge-independent intensity profile, have important applications in enhancing communication capacity and optimizing particle manipulation. In this paper, metal-insulator-metal copper-coin type reflective metasurfaces are proposed to generate perfect composite vortex beams in X-band.
View Article and Find Full Text PDFACS Earth Space Chem
January 2025
School of Chemistry, Norwich Research Park, University of East Anglia, Norwich NR4 7TJ, U.K.
2-Cyanoindene is one of the few specific aromatic or polycyclic aromatic hydrocarbon (PAH) molecules positively identified in Taurus molecular cloud-1 (TMC-1), a cold, dense molecular cloud that is considered the nearest star-forming region to Earth. We report cryogenic mid-infrared (550-3200 cm) and visible (16,500-20,000 cm, over the ← electronic transition) spectra of 2-cyanoindene radical cations (2CNI), measured using messenger tagging (He and Ne) photodissociation spectroscopy. The infrared spectra reveal the prominence of anharmonic couplings, particularly over the fingerprint region.
View Article and Find Full Text PDFJ Neurosci
January 2025
Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Dr. Houghton, MI 49931.
Deep brain stimulation (DBS) effectively treats motor symptoms of advanced Parkinson's disease (PD), with the globus pallidus interna (GPi) commonly targeted. However, its therapeutic mechanisms remain unclear. We employed optogenetic stimulation in the entopeduncular nucleus (EP), the rat homologue of GPi, in a unilateral 6-OHDA lesioned female Sprague Dawley rat model of PD.
View Article and Find Full Text PDFRMD Open
January 2025
TYKS laboratories, Clinical Microbiology, Turku University Hospital, Turku, Finland.
Objectives: We assessed the positive predictive value (PPV) of 17 myositis antibodies for having a diagnosis of myositis and other myositis-spectrum conditions (interstitial lung disease (ILD), connective tissue diseases (CTD), malignancy) and evaluated the impact of semiquantitative classification and antibody overlap on the PPVs.
Materials And Methods: We retrospectively identified 1068 individuals ≥18 years who tested positive for ≥1 antibody in the EUROLINE myositis line blot assay or positive for anti-3-hydroxy-3-methylglutaryl-CoA reductase (HMGCR) in an ELISA-based test between 2015 and 2020 in 15 out of the 20 hospital districts in Finland. We extracted clinical diagnoses from the Care Register for Health Care between January 2013 and June 2022.
Rev Sci Instrum
January 2025
The State Key Laboratory of Complex Electromagnetic Environment Effects on Electronic and Information System, Luoyang 471004, China.
A multi-band high-sensitivity microwave sensor is reported. The two resonance units are based on complementary square spiral resonators (CSSRs) and produce four measurement bands through parasitic resonances. The four frequency bands are 2.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!