Purpose: To evaluate the image quality and radiation dose exposure of low-dose coronary CTA (cCTA) study, reconstructed with the new model-based iterative reconstruction algorithm (IMR), compared with standard hybrid-iterative reconstruction (iDose) cCTA in patients with suspected coronary artery disease.

Materials And Methods: Ninety-eight patients with an indication for coronary CT study were prospectively enrolled. Fifty-two patients (study group) underwent 256-MDCT low-dose cCTA (80 kV; automated-mAs; 60 mL of CM, 350 mgL/mL) with prospective ECG-triggering acquisition and IMR. A control group of 46 patients underwent 256-MDCT standard prospective ECG-gated protocol (100 kV; automated-mAs; 70 mL of CM, 400 mgL/mL; iDose). Subjective and objective image quality (attenuation value, SD, SNR and CNR) were evaluated by two radiologists subjectively. Radiation dose exposure was quantified as DLP, CTDIvol and ED.

Results: Mean values of mAs were significantly lower for IMR-cCTA (167 ± 62 mAs) compared to iDose-cCTA (278 ± 55 mAs), p < 0.001. With a significant reduction of 38% in radiation dose exposure (DLP: IMR-cCTA 91.7 ± 26 mGy cm vs. iDose-cCTA 148.6 ± 35 mGy cm; p value < 0.001), despite the use of different CM, we found higher mean attenuation values of the coronary arteries in IMR group compared to iDose (mean density in LAD: 491HU IMR-cCTA vs. 443HU iDose-cCTA; p = 0.03). We observed a significant higher value of SNR and CNR in study group due to a lower noise level. Qualitative analysis did not reveal any significant differences between the two groups (p = 0.23).

Conclusions: Low-dose cCTA study combined with IMR reconstruction allows to correctly evaluate coronary arteries disease, offering high-quality images and significant radiation dose exposure reduction (38%), as compared to standard cCTA protocol.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11547-018-0964-6DOI Listing

Publication Analysis

Top Keywords

reconstruction algorithm
12
image quality
12
model-based iterative
8
iterative reconstruction
8
coronary artery
8
standard hybrid-iterative
8
hybrid-iterative reconstruction
8
radiation dose
8
dose exposure
8
underwent 256-mdct
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!