Purpose: Radioiodine has been used for the treatment of benign thyroid diseases for over 70 years. However, internationally, there is no common standard for pretherapeutic dosimetry to optimally define the individual therapy activity. Here, we analyze how absorbed tissue doses are influenced by different approaches to pretherapeutic activity calculation of varying complexity.

Methods: Pretherapeutic determination of treatment activity was retrospectively recalculated in 666 patients who had undergone radioiodine therapy for benign thyroid diseases (Graves' disease, non-toxic goiter, and uni- and multinodular goiter). Approaches considering none, some, or all of a set of individual factors, including target volume, maximum radioiodine uptake, and effective half-life, were applied. Assuming individually stable radioiodine kinetics, which had been monitored twice a day under therapy, hypothetically achieved tissue doses based on hypothetically administered activities resulting from the different methods of activity calculation were compared to intended target doses.

Results: The Marinelli formula yields the smallest deviations of hypothetically achieved doses from intended target doses. Approaches taking individual target volume into consideration perform better than fixed therapy activities, which lead to high variances in achieved doses and high deviations of hypothetically achieved doses from intended target doses.

Conclusion: Elaborate pretherapeutic dose planning, taking individual radioiodine uptake, half-life, and target volume into consideration, should be used whenever possible. The use of disease-specific fixed activities cannot be recommended. Deviations of achieved tissue doses from target doses can already be significantly lowered by application of volume-adapted treatment activities if more elaborate means are not available.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6289932PMC
http://dx.doi.org/10.1186/s40658-018-0231-xDOI Listing

Publication Analysis

Top Keywords

achieved doses
16
benign thyroid
12
thyroid diseases
12
tissue doses
12
target volume
12
hypothetically achieved
12
intended target
12
doses
9
treatment activities
8
radioiodine therapy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!