A Self-Pumping Dressing for Draining Excessive Biofluid around Wounds.

Adv Mater

CAS Key Laboratory of Bio-inspired Materials and Interfacial Science, CAS Center for Excellence in Nanoscience, Technical Institute of Physics and Chemistry, University of Chinese Academy of Sciences, Beijing, 100190, P. R. China.

Published: February 2019

Excessive biofluid around wounds often causes infection and hinders wound healing. However, the intrinsic hydrophilicity of the conventional dressing inevitably retains excessive biofluid at the interface between the dressing and the wound. Herein, a self-pumping dressing is reported, by electrospinning a hydrophobic nanofiber array onto a hydrophilic microfiber network, which can unidirectionally drain excessive biofluid away from wounds and finally accelerate the wound healing process. The hydrophilic microfiber network offers a draining force to pump excessive biofluid through the hydrophobic nanofiber array, which can further keep those pumped biofluids from rewetting the wounds. In the proof of concept, the self-pumping dressing unidirectionally drains the biofluid from murine dorsum wounds, thereby resulting in faster wound healing than conventional dressings. This unique self-pumping dressing has enormous potential to be a next-generation dressing for healing wounds clinically.

Download full-text PDF

Source
http://dx.doi.org/10.1002/adma.201804187DOI Listing

Publication Analysis

Top Keywords

excessive biofluid
20
self-pumping dressing
16
biofluid wounds
12
wound healing
12
hydrophobic nanofiber
8
nanofiber array
8
hydrophilic microfiber
8
microfiber network
8
biofluid
6
wounds
6

Similar Publications

Transparent and Mechanically Robust Janus Nanofiber Membranes for Open Wound Healing and Monitoring.

ACS Appl Mater Interfaces

November 2024

Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9, Canada.

The electrospun nanofiber membrane has demonstrated great potential for wound management due to its porous structure, large surface area, mechanical strength, and barrier properties. However, there is a need to develop transparent bioactive nanofibers with strong mechanical properties to facilitate the monitoring of the healing process. In this study, we present an electrospinning-based method for creating transparent (∼80-90%), strong (∼11-13 MPa), and Janus nanofiber membranes.

View Article and Find Full Text PDF

Periodontitis is a chronic inflammation caused by periodontopathogenic bacteria in the dental biofilm, and also involves the inflammatory-immune response of the host. Polymorphonuclear neutrophils (PMNs) play essential roles in bacterial clearance by multiple mechanisms, including the formation of neutrophil extracellular traps (NETs) that retain and destroy pathogens. During PD progression, the interaction between PMNs, NETs, and bacteria leads to an exaggerated immune response and a prolonged inflammatory state.

View Article and Find Full Text PDF

Background and objective Workplace accidents (WPAs) are a common problem worldwide. They are often considered a public health concern due to the potential transmission of infections such as HIV, hepatitis B, and hepatitis C through sharp devices or direct exposure to biofluids. Post-exposure prophylaxis (PEP) has demonstrated effectiveness in such instances, especially immediately after exposure.

View Article and Find Full Text PDF

Associations between Non-Essential Trace Elements in Women's Biofluids and IVF Outcomes in Euploid Single-Embryo Transfer Cycles.

J Xenobiot

August 2024

IVI-RMA Global Research Alliance, IVI Foundation, Instituto de Investigación Sanitaria La Fe (IIS La Fe), 46026 Valencia, Spain.

Previous studies have found inconsistent associations between heavy metals and metalloids (cadmium, lead, mercury, and arsenic), and reproductive outcomes. The biofluid concentrations of ten non-essential trace elements (Hg, Pb, As, Ba, Sr, Rb, Cs, Sn, Ni, and Co) were evaluated in 51 Spanish women undergoing ICSI, PGT-A, and SET/FET. Nine out of ten non-essential elements were detectable in follicular fluid, whole blood, and urine collected the day of vaginal oocyte retrieval (VOR) and the day of embryo transfer and then analyzed by ICP-MS or Tricell DMA-80 for mercury.

View Article and Find Full Text PDF

A poly (lactic-co-glycolic acid) self-pumping Janus dressing with bidirectional biofluid transport for diabetic wound healing via anti-bacteria and pro-angiogenesis.

Int J Biol Macromol

August 2024

State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, PR China; Foshan Xianhu Laboratory of the Advanced Energy Science and Technology Guangdong Laboratory, Xianhu hydrogen Valley, Foshan 528200, PR China; Hainan Institute, Wuhan University of Technology, Sanya 572000, PR China; Biomedical Materials and Engineering Research Center of Hubei Province, Wuhan University of Technology, Wuhan 430070, PR China; Department of Stomatology, Zhongnan Hospital of Wuhan University, Wuhan 430060, PR China. Electronic address:

Diabetic wound healing poses a substantial challenge owing to bacterial infections, insufficient angiogenesis, and excessive exudates. Currently, most of the clinical dressings used for diabetic wounds are still conventional dressings such as gauze. In this study, a three-layer Janus dressing was developed via continuous electrostatic spinning.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!