The tissue-equivalent proportional counter (TEPC) is the most accurate device for measuring the microdosimetric properties of a particle beam but, since the lower operation limit of common TEPCs is ~0.3 μm, no detailed information on the track structure of the impinging particles can be obtained. The pattern of particle interactions at the nanometric level is measured directly by only three different nanodosimeters worldwide: practical instruments are not yet available. In order to partially fill the gap between microdosimetry and track-nanodosimetry, a low-pressure avalanche-confinement TEPC was designed and constructed for simulating tissue-equivalent sites down to the nanometric region. The present paper aims at describing the response of this TEPC in the range 0.3 μm-25 nm to a 62 MeV/n 4He ion beam. The experimental results, for depths near the Bragg peak, show good agreement with FLUKA simulations and suggest that, for smaller depths, the distribution is highly influenced by secondary electrons.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncy230DOI Listing

Publication Analysis

Top Keywords

avalanche-confinement tepc
8
ion beam
8
microdosimetry nanometric
4
nanometric scale
4
scale avalanche-confinement
4
tepc
4
tepc response
4
response helium
4
helium ion
4
beam tissue-equivalent
4

Similar Publications

Microdosimetry of an accelerator based thermal neutron field for Boron Neutron Capture Therapy.

Appl Radiat Isot

April 2022

Istituto Nazionale di Fisica Nucleare INFN, Laboratori Nazionali di Legnaro, Viale Dell'Università 2, Legnaro (Padova), Italy.

The MUNES project (MUltidisciplinary NEutron Source) aims at the realization of an intense accelerator-based source of thermal neutrons, suitable for Boron Neutron Capture Therapy (BNCT). This exploits the interaction of 5 MeV protons onto a beryllium target, producing a fast neutron spectrum, which is moderated to the thermal range by a large assembly made of a Polytetrafluoroethylene (PTFE) tank filled with heavy water, surrounded by graphite blocks. The thermal neutron field is extracted through a bismuth beam port.

View Article and Find Full Text PDF

MICRODOSIMETRY AT NANOMETRIC SCALE WITH AN AVALANCHE-CONFINEMENT TEPC: RESPONSE AGAINST A HELIUM ION BEAM.

Radiat Prot Dosimetry

May 2019

INFN, Laboratori Nazionali del Sud, via Santa Sofia 62, Catania, Italy.

The tissue-equivalent proportional counter (TEPC) is the most accurate device for measuring the microdosimetric properties of a particle beam but, since the lower operation limit of common TEPCs is ~0.3 μm, no detailed information on the track structure of the impinging particles can be obtained. The pattern of particle interactions at the nanometric level is measured directly by only three different nanodosimeters worldwide: practical instruments are not yet available.

View Article and Find Full Text PDF

Tissue equivalent proportional counter (TEPC) is the most accurate device for measuring the microdosimetric properties of a particle beam, nevertheless no detailed information on the track structure of the impinging particles can be obtained, since the lower operation limit of common TEPCs is ~0.3 μm. On the other hand, the pattern of particle interactions at the nanometer level is measured by only three different nanodosimeters worldwide: practical instruments are not yet available.

View Article and Find Full Text PDF

Nanodosimetric measurements with an avalanche confinement TEPC.

Radiat Prot Dosimetry

March 2003

INFN Laboratori Nazionali di Legnaro, Via Romea 4, I-35020 Legnaro, Padova, Italy.

This paper illustrates a tissue-equivalent proportional counter designed to have high gas gain and good energy resolution at nanometric simulated site sizes. Microdosimetric neutron and gamma spectra were measured in dimethyl ether and in propane-based tissue-equivalent gas mixture down to 35 nm. The comparison of experimental data with the results of Monte Carlo calculations shows a satisfactory agreement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?