A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

New perspectives in the use of laser diode transscleral cyclophotocoagulation. A prospective single center observational cohort study. | LitMetric

New perspectives in the use of laser diode transscleral cyclophotocoagulation. A prospective single center observational cohort study.

Rom J Morphol Embryol

Department of Neurology, "Victor Babeş" University of Medicine and Pharmacy, "Pius Brînzeu" Emergency County Clinical Hospital, Timişoara, Romania; Department of Ophthalmology, "Carol Davila" University of Medicine and Pharmacy, Bucharest, Romania;

Published: January 2019

Purpose: The paper intends to present the results of using new methods of a new generation diode laser transscleral cyclophotocoagulation (TSCPC) in patients with different types of glaucoma.

Patients, Materials And Methods: There have been treated 53 eyes from 59 patients with glaucoma refractory to medical, laser or surgical treatment. We have used the newest generation of 810 nm wavelength diode laser. There have been used two protocols of continuous-wave diode laser emitting radiation for cyclophotocoagulation. The first technique - the standard cyclophotocoagulation (high power and low exposure duration) - has been used for the eyes with limited visual function [visual acuity (VA) extremely low or eyes disorganized]. The second technique - slow coagulation, also named "slow burn" (lower power and greater exposure duration) - has been used for the eyes with apparently better visual prognosis (VA≥20∕400). For evaluation, we followed both subjective parameters (eye pain decrease) and objective parameters [intraocular pressure (IOP) lowering and VA evolution]. Patients have been evaluated before laser intervention and postoperative at one, three and six months.

Results: IOP has significantly decreased in both patient groups. In the eyes with better visual function (VA≥1∕20), where we have used the "slow coagulation" technique, we found no decrease of VA. Eye pain has disappeared in almost all treated cases.

Conclusions: The diode laser TSCPC is an efficient method of lowering IOP and decreasing eye pain. The "slow burn" technique has been shown its efficiency for extending the indications of cyclophotocoagulation also in glaucomatous eyes with better functional prognosis.

Download full-text PDF

Source

Publication Analysis

Top Keywords

diode laser
16
eyes better
12
eye pain
12
transscleral cyclophotocoagulation
8
exposure duration
8
duration eyes
8
visual function
8
"slow burn"
8
better visual
8
laser
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!