Background: It remains controversial if arterial perfusion in addition to portal vein perfusion during machine preservation improves liver graft quality. Comparative studies using both techniques are lacking. We studied the impact of using single or dual machine perfusion of donation after circulatory death rat livers. In addition, we analyzed the effect of pulsatile versus continuous arterial flow.

Methods: Donation after circulatory death rat livers (n = 18) were preserved by 6 hours cold storage, followed by 1 hour subnormothermic machine perfusion (20°C, pressure of 40/5 mm Hg) and 2 hours ex vivo warm reperfusion (37°C, pressure of 80/11 mm Hg, 9% whole blood). Machine preservation was either through single portal vein perfusion (SP), dual pulsatile (DPP), or dual continuous perfusion (DCP) of the portal vein and hepatic artery. Hydrodynamics, liver function tests, histopathology, and expression of endothelial specific genes were assessed during 2 hours warm reperfusion.

Results: At the end of reperfusion, arterial flow in DPP livers tended to be higher compared to DCP and SP grafts. However, this difference was not significant nor was better flow associated with better outcome. No differences in bile production or alanine aminotransferase levels were observed. SP livers had significantly lower lactate compared to DCP, but not DPP livers. Levels of Caspase-3 and tumor necrosis factor-α were similar between the groups. Expression of endothelial genes Krüppel-like-factor 2 and endothelial nitric oxide synthase tended to be higher in dual perfused livers, but no histological evidence of better preservation of the biliary endothelium or vasculature of the hepatic artery was observed.

Conclusions: This study shows comparable outcomes after using a dual or single perfusion approach during end-ischemic subnormothermic liver machine preservation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6233661PMC
http://dx.doi.org/10.1097/TXD.0000000000000840DOI Listing

Publication Analysis

Top Keywords

machine preservation
16
portal vein
12
single dual
8
perfusion
8
end-ischemic subnormothermic
8
subnormothermic liver
8
liver machine
8
vein perfusion
8
machine perfusion
8
donation circulatory
8

Similar Publications

Improved Intelligent Condition Monitoring with Diagnostic Indicator Selection.

Sensors (Basel)

December 2024

Faculty of Mechanical Engineering and Robotics, AGH University of Krakow, 30-059, Krakow, Poland.

In this study, a predictive maintenance (PdM) system focused on feature selection for the detection and classification of simulated defects in wind turbine blades has been developed. Traditional PdM systems often rely on numerous, broadly chosen diagnostic indicators derived from vibration data, yet many of these features offer little added value and may even degrade model performance. General feature selection methods might not be suitable for PdM solutions, as information regarding observed faults is often misinterpreted or lost.

View Article and Find Full Text PDF

An intelligent transportation system (ITS) offers commercial and personal movement through the smart city (SC) communication paradigms with hassle-free information sharing. ITS designs and architectures have improved via information and communication technologies in recent years. The information shared through the communication medium in SCs is exposed to adversary risk, resulting in privacy issues.

View Article and Find Full Text PDF

Non-small cell lung adenocarcinoma (LUAD) is a markedly heterogeneous disease, with its underlying molecular mechanisms and prognosis prediction presenting ongoing challenges. In this study, we integrated data from multiple public datasets, including TCGA, GSE31210, and GSE13213, encompassing a total of 867 tumor samples. By employing Mendelian randomization (MR) analysis, machine learning techniques, and comprehensive bioinformatics approaches, we conducted an in-depth investigation into the molecular characteristics, prognostic markers, and potential therapeutic targets of LUAD.

View Article and Find Full Text PDF

With the advancement of this digital era and the emergence of DApps and Blockchain, secure, robust and transparent network transaction has become invaluable today. These traditional methods of securing the transactions and maintaining transparency have encountered many challenges. It includes some such issues as follows: data privacy, centralized vulnerability, inefficiency in fraud detection and much more.

View Article and Find Full Text PDF

Liver Transplantation after Ex Vivo normothermic machine preservation without re-cooling the graft: A clinical series from a single center.

Liver Transpl

January 2025

Abdominal Center Department, Istituto di Ricovero e Cura a Carattere Scientifico-Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione (IRCCS ISMETT), University of Pittsburgh Medical Center Italy (UPMCI), Palermo, Italy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!