Dysphagia is the major pathophysiologic mechanism leading to aspiration pneumonia in the elderly. Elderly people with dysphagia who show low levels of the cough peak flow (CPF) are at greater risk for aspiration pneumonia. It has been reported that CPF values were significantly lower in the "soft" versus "hard" mode of a pressure-relieving air mattress in healthy volunteers in a supine position. Parameters such as spinal curvature, however, were not evaluated in detail. In this study, we clarified whether the changes in posture associated with two different firmness levels of a pressure-relieving air mattress were associated with cough production and related factors in the elderly with dysphagia. The body sinking distance, pelvic tilt angle, and immersion of the lumbar spine were measured to evaluate changes in posture. Forty subjects met the study criteria for dysphagia. The "soft" mode showed significantly lower CPF values than the "hard" mode (soft 274.9 ± 107.2 L/min vs. hard 325.0 ± 99.5 L/min, MD 50.0 95%CI 33.1-66.9 P < 0.001). Values of forced vital capacity (FVC) and maximal inspiratory pressure (PImax) were significantly lower in the "soft" mode than in the "hard" mode (MD 0.10 95%CI 0.04-0.17, P = 0.002, MD 3.2 95%CI 0.9-5.5, P = 0.007, respectively). Although there was no significant difference between the two firmness levels, maximal expiratory pressure (PEmax) values also tended to be lower in the "soft" than in the "hard" mode, (MD 2.9 95%CI -0.6-6.3 P = 0.1). At both firmness levels, CPF values were significantly correlated with FVC, PImax, and PEmax. The difference in sinking distance in the anterior superior iliac spine was significantly larger than that in the lesser tubercle of the humerus and patella. Additionally, in the soft mode, the pelvic tilt angle and contact area around the lumbar spine were significantly larger than those observed in the "hard" mode. Parameters associated with the production of cough, including inspiratory muscle strength, lung volume, and ultimately CPF, may be affected by immersion of the lumbar spine and curvature of the spine that results from the "soft" mode in elderly patients with dysphagia.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6289577 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0208895 | PLOS |
Afr J Disabil
December 2024
Department of Audiology, Faculty of Human and Community Development, University of the Witwatersrand, Braamfontein, South Africa.
Background: Parents of Deaf or hard-of-hearing (DHH) children are faced with a plethora of overwhelming decisions concerning their children, particularly during the early stages of development. Among these decisions are those concerning assistive devices and the modes of communication for their child.
Objectives: The aim of this study was to explore the perceptions of parents of DHH children towards the various modes of communication for their children within the South African context.
A high security physical layer encryption scheme for dual-mode orthogonal frequency division multiplexing with index modulation (DM-OFDM-IM) in magnetic induction communication is proposed. The scheme utilizes DM-OFDM-IM, where subcarriers within each subblock are divided into two groups, each modulated by distinct signal constellations. DM-OFDM-IM leverages the sequential information from the modulated constellation to transmit extra information, leading to a substantial enhancement in spectral efficiency.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, China.
Photonic manipulation of large-capacity data with the advantages of high speed and low power consumption is a promising solution for explosive growth demands in the era of post-Moore. A well-developed lithium-niobate-on-insulator (LNOI) platform has been widely explored for high-performance electro-optic (EO) modulators to bridge electrical and optical signals. However, the photonic waveguides on the x-cut LNOI platform suffer serious polarization-mode conversion/coupling issues because of strong birefringence, making it hard to realize large-scale integration.
View Article and Find Full Text PDFSensors (Basel)
December 2024
School of Energy and Power Engineering, Beihang University, Beijing 100191, China.
Corrosion damage presents significant challenges to the safety and reliability of connected vehicles. However, traditional non-destructive methods often fall short when applied to complex automotive structures, such as bolted lap joints. To address this limitation, this study introduces a novel corrosion monitoring approach using Lamb wave-based weighted fusion imaging methods.
View Article and Find Full Text PDFJ Prosthet Dent
January 2025
Assistant Professor, Department of Prosthodontic, College of Dental Medicine, Rangsit University, Phatum Thani, Thailand. Electronic address:
Statement Of Problem: Comprehensive data are needed on the performance of chemically activated, chairside hard reline materials when used with computer-aided design and computer-aided manufacturing (CAD-CAM) milled polymethyl methacrylate (PMMA) denture bases and conventionally processed bases. This lack of data affects decisions regarding the chairside reline material to be used for improving the fit and retention of relined complete dentures.
Purpose: The purpose of this in vitro study was to evaluate and compare the shear bond strength (SBS) of 3 chemically activated, chairside hard reline materials on CAD-CAM milled and conventional heat-polymerized PMMA denture bases.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!