A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigating the subjective cooling effect of eyelid cleansing gel on eyelid and ocular surface temperature. | LitMetric

Investigating the subjective cooling effect of eyelid cleansing gel on eyelid and ocular surface temperature.

Cont Lens Anterior Eye

Ophthalmic Research Group, School of Life & Health Sciences, Aston University, Birmingham, B4 7ET, United Kingdom; Thea Pharmaceuticals Limited, Keele University Science & Innovation Park, Newcastle-Under-Lyme, ST5 5NT, United Kingdom.

Published: August 2019

Purpose: To investigate if the application of Blephagel, an eyelid cleansing gel, causes subjective and/or objective cooling effects by measuring ocular symptomology and temperature.

Methods: Twenty-five healthy subjects underwent baseline non-invasive temperature measurements on the closed upper eyelid (centrally, nasally, and temporally) and ocular surface temperature (OST) on both eyes using an infrared camera. A standard application of Blephagel was then applied to the closed upper eyelid and eyelashes with a sterile cotton-wool to one eye selected at random. Temperature measures were then repeated on both eyes after 30-60, 120-150, and 180-210 s. At each interval, subjects rated the comfort and any cooling sensation of each eye on a 0-10 scale.

Results: After application of the gel, there was a significant difference in temperature at all locations on the eyelid between the test and control eyes over time (F = 9.322, p < 0.001). Post hoc analysis revealed this was significant from 30 to 60 s interval (36.3 ± 1.1 °C versus 37.2 ± 0.7 °C; p < 0.001) and the 120-150 s interval (36.8 ± 0.8 °C versus 37.2 ± 0.6 °C; p < 0.001). There was no significant variation between the OST locations over time (F = 3.350, p = 0.07). With respect to symptoms, there was a significant increase in cooling sensation in the test eye compared to the control eye over time (F = 10.438, p < 0.001), that remained throughout the experiment.

Conclusions: Blephagel produces a reduction in temperature of the eyelids that is accompanied with a subjective cooling sensation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clae.2018.12.001DOI Listing

Publication Analysis

Top Keywords

eyelid cleansing
8
cleansing gel
8
ocular surface
8
surface temperature
8
application blephagel
8
closed upper
8
upper eyelid
8
eyelid
6
temperature
5
investigating subjective
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!