A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of the immunohistochemical expression of programmed death ligand 1 (PD-L1) on cytological smears in advanced non small cell lung cancer. | LitMetric

Introduction The assessment of PD-L1 expression by immunohistochemistry is mandatory for the administration as first-line therapy of the anti PD-1 check-point inhibitor Pembrolizumab in patients with advanced non-small-cell lung cancer (NSCLC). Currently, only formalin-fixed paraffin-embedded samples are acceptable for PD-L1 immunostaining with the anti-PD-L1 antibodies 22-C3 and SP263. We investigated retrospectively the accuracy of the anti PD-L1 antibodies 22-C3, 28-28, SP263 in 50 paired histological samples and cytological smears of NSCLC patients. Results The accuracy of the three antibodies for the detection of PD-L1 in histological samples was higher for the antibody SP263 (AUC/ROC = 1) compared to the clones 28-8 (AUC/ROC =,991) and 22-C3 (AUC/ROC =,942). The overall concordance between histological samples and cytological smears using the SP263 clone was moderate (kappa = 0,364). However when the cyto-histological concordance was calculated using just the <50% vs ≥50% cut-off the agreement (kappa = 0.626) was good. The accuracy of the antibody SP263 in cytological smears was good (AUC/ROC =,921). A fluorescent in situ hybridization analysis on 10 histological cases positive for PD-L1 at immunohistochemistry showed amplification of the CD274 gene only in one case. Conclusions Immunocytochemical staining for PD-L1 in diagnostic cytological smears of NSCLC is feasible and applicable at least using the >50% cancer cell cut-off. The three antibodies SP263, 22-C3 and 28-8 are all suitable for the diagnostic detection of PD-L1 on tissue sections with a superiority of the SP263 clone. The implementation of PD-L1 immunocytochemistry on cytological smears will likely expand the pool of NSCLC patients candidate to first-line immunotherapy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.lungcan.2018.10.017DOI Listing

Publication Analysis

Top Keywords

cytological smears
16
histological samples
12
lung cancer
8
antibodies 22-c3
8
samples cytological
8
nsclc patients
8
three antibodies
8
detection pd-l1
8
sp263 clone
8
pd-l1
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!