Background and purpose - Hydroxyapatite (HA)-coated implants have been associated with high polyethylene wear in hip arthroplasties. HA coating as a promoter of wear in knee arthroplasties has not been investigated. We compared the wear-rate of the polyethylene bearing for cemented and cementless HA-coated Oxford medial unicondylar knee arthroplasties (UKA). Secondarily, we investigated whether wear-rates were influenced by overhang or impingement of the bearing. Patients and methods - 80 patients (mean age 64 years), treatment-blinded, were randomized to 1 of 3 Oxford medial UKA versions: cemented with double-pegged or single-pegged femoral component or cementless HA-coated with double-pegged femoral component (ratios 1:1:1). We compared wear between the cemented (n = 55) and cementless group (n = 25) (ratio 2:1). Wear, impingement, and overhang were quantified between surgery and 5-year follow-up using radiostereometry. Clinical outcome was evaluated with the Oxford Knee Score. Results - The mean wear-rate for patients without bearing overhang was 0.04 mm/year (95% CI 0.02-0.07) for the cemented group and 0.05 mm/year (CI 0.02-0.08) for the cementless group. The mean difference in wear was 0.008 mm/year (CI -0.04 to 0.03). No impingement was identified. Half of the patients had medial bearing overhang, mean 2.5 mm (1-5). Wear increased by 0.014 mm/year for each mm increment in overhang. The mean Oxford Knee Score was 39 for the cementless group and 38 for the cemented group at the 5-year follow-up. Interpretation - The wear-rates were similar for the 2 fixation methods, which supports further use of the cementless Oxford medial UKA. However, a caveat is a relatively large 95% CI of the mean difference in wear-rate. Component size and position is important as half of the patients presented with an additional increase in wear-rate due to medial bearing overhang.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6366473PMC
http://dx.doi.org/10.1080/17453674.2018.1543757DOI Listing

Publication Analysis

Top Keywords

oxford medial
16
cemented cementless
12
medial uka
12
5-year follow-up
12
cementless group
12
bearing overhang
12
polyethylene wear
8
wear cemented
8
cementless oxford
8
knee arthroplasties
8

Similar Publications

Objective: Gap balancing is a vital process during mobile-bearing unicompartmental knee arthroplasty (MB-UKA). However, this process commonly depends on the surgeon's experience and lacks specific unified standards. This study aimed to propose and evaluate a novel "measured resection" method for gap balance in MB-UKA.

View Article and Find Full Text PDF

Objective: The effectiveness and optimal stimulation site of deep brain stimulation (DBS) for central poststroke pain (CPSP) remain elusive. The objective of this retrospective international multicenter study was to assess clinical as well as neuroimaging-based predictors of long-term outcomes after DBS for CPSP.

Methods: The authors analyzed patient-based clinical and neuroimaging data of previously published and unpublished cohorts from 6 international DBS centers.

View Article and Find Full Text PDF
Article Synopsis
  • Knee pain often involves varus deformity and unicompartmental osteoarthritis, where high tibial valgus osteotomy (HTO) has emerged as an effective treatment option to delay joint replacement.
  • A case report highlighted two patients with bilateral knee arthritis who underwent medial opening-wedge high tibial osteotomy using Dr. Saigal's plate, both achieving good range of motion and minimal complications post-surgery.
  • Comprehensive evaluations, including radiological assessments and specific surgical techniques like the Miniaci Method, were employed to ensure successful outcomes, with both patients showing significant improvement after one year.
View Article and Find Full Text PDF

Metal-backed versus all-poly tibia in the original cartier unicompartmental knee arthroplasty: outcomes and survivorship at long-term follow-up.

Arch Orthop Trauma Surg

December 2024

Sezione di Chirurgia Protesica ad Indirizzo Robotico Unità di Traumatologia dello Sport, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy.

Purpose: Unicompartmental knee arthroplasty (UKA) is a viable option for localized osteoarthritis (OA) or avascular osteonecrosis with several advantages over total knee arthroplasty (TKA). UKA implants may feature a tibial component either all-polyethylene (AP) or metal-backed (MB). This study aims to retrospectively compare the clinical outcomes and survivorship of 74 UKAs over 16 years, focusing on comparing the results and survivorship of MB versus AP tibial tray.

View Article and Find Full Text PDF

Comparison of the effects of orthoses on hallux valgus angle and plantar pressure in individuals with hallux valgus.

Prosthet Orthot Int

December 2024

Department of Orthosis and Prosthetics, School of Health Sciences, Istanbul Medipol University, Istanbul, Turkey.

Background: Hallux valgus (HV) is a condition characterized by the lateral deviation of the first phalanx and medial deviation of the first metatarsal, leading to subluxation of the first metatarsophalangeal joint. Various orthotic applications are employed in the treatment of HV deformity. This study aimed to compare the effects of a toe separator (TS) and dynamic orthosis (DO) on hallux valgus angle (HVA), plantar pressure (PP), and quality of life (QoL).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!