Background: Septicemic melioidosis caused by Burkholderia pseudomallei is a serious cause of morbidity and mortality. An effective, rapid and simple diagnostic method is required for detection of B. pseudomallei infection.

Objective: To develop immunomagnetic beads (IMB) coupled with ELISA (IMB-ELISA) for detection of B. pseudomallei in blood samples of patients with suspected melioidosis.

Methods: For separation of B. pseudomallei from buffer, blood samples and hemoculture, 200 nm immunomagnetic beads (IMBs) coated with 4B11 monoclonal antibody (4B11-IMBs) against exopolysaccharide antigens were used. The detection was done by an ELISA based biotin-streptavidin system. The sensitivity and specificity were evaluated.

Results: 4B11-IMBs (100 μg) were successfully developed and used for detection of B. pseudomallei in 1 ml samples. Transmission electron microscopy (TEM) imaging demonstrated B. pseudomallei was captured by 4B11-IMBs. The IMBs showed high capture efficiency (98%) with B. pseudomallei in buffer. The IMB-ELISA assay was highly specific for B. pseudomallei. It showed no cross-reactions with other bacteria, except B. mallei. The limits of the B. pseudomallei assay detection for detecting B. pseudomallei in either buffer solution or blood was 102 CFU/ml. The IMB-ELISA detection sensitivity in blood samples was 44.5%. Although it did not give the highest sensitivity, it was useful for detection with hemoculture that was faster than conventional methods.

Conclusion: This study suggests the IMB-ELISA assay offers a simple and highly specific method with a turnaround time of 6 h for detection of B. pseudomallei. The developed assay can be applied in hospitals for surveillance of B. pseudomallei.

Download full-text PDF

Source
http://dx.doi.org/10.12932/AP-080518-0307DOI Listing

Publication Analysis

Top Keywords

blood samples
16
detection pseudomallei
16
pseudomallei
13
pseudomallei buffer
12
detection
9
burkholderia pseudomallei
8
pseudomallei blood
8
immunomagnetic beads
8
imb-elisa detection
8
imb-elisa assay
8

Similar Publications

External delay and dispersion correction of automatically sampled arterial blood with dual flow rates.

Biomed Phys Eng Express

January 2025

Brain Health Imaging Centre, Centre for Addiction and Mental Health, B68-250 College St, Toronto, Ontario, M5T 1R8, CANADA.

Objective: Arterial sampling for PET imaging often involves continuously measuring the radiotracer activity concentration in blood using an automatic blood sampling system (ABSS). We proposed and validated an external delay and dispersion correction procedure needed when a change in flow rate occurs during data acquisition. We also measured the external dispersion constant of [11C]CURB, [18F]FDG, [18F]FEPPA, and [18F]SynVesT-1.

View Article and Find Full Text PDF

Colorectal cancer (CRC) is one of the most common cancers worldwide and inflammation is believed to play an important role in CRC. In this study, we comprehensively analyzed the causal association between 91 circulating inflammatory cytokines and the risk of CRC using Mendelian randomization (MR). Based on genome-wide association study summary statistics, we examined the causal effects of 91 circulating inflammatory cytokines on CRC.

View Article and Find Full Text PDF

Associations of cathepsins with pulmonary arterial hypertension mediated by circulating metabolites: A Mendelian randomization study.

Medicine (Baltimore)

January 2025

National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China.

The correlation between cathepsins and pulmonary arterial hypertension (PAH) is well-established, but the causative link between them remains uncertain. This study aimed to explore the causal role of circulating metabolites mediating cathepsins in PAH using Mendelian randomization (MR). A 2-sample 2-step MR method was used to identify causal relationship between cathepsins and PAH; causal relationship between circulating metabolites and PAH; and mediated effects of these circulating metabolites.

View Article and Find Full Text PDF

The roles of STAT1, CASP8, and MYD88 in the care of ischemic stroke.

Medicine (Baltimore)

January 2025

Nerve Rehabilitation Center, Beijing Rehabilitation Hospital Affiliated to Capital Medical University, Xixia Zhuang, Badachu, Shijingshan District, Beijing, China.

Ischemic stroke is caused by blockage of blood vessels in brain, affecting normal function. The roles of Signal Transformer and Activator of Transcription 1 (STAT1), CASP8, and MYD88 in ischemic stroke and its care are unclear. The ischemic stroke datasets GSE16561 and GSE180470 were found from the Gene Expression Omnibus database.

View Article and Find Full Text PDF

Ultrasensitive Detection of Circulating Plasma Cells Using Surface-Enhanced Raman Spectroscopy and Machine Learning for Multiple Myeloma Monitoring.

Anal Chem

January 2025

Key Laboratory of OptoElectronic Science and Technology for Medicine of Ministry of Education, Fujian Provincial Key Laboratory of Photonics Technology, Fujian Normal University, Fuzhou, Fujian 350117, China.

Multiple myeloma is a hematologic malignancy characterized by the proliferation of abnormal plasma cells in the bone marrow. Despite therapeutic advancements, there remains a critical need for reliable, noninvasive methods to monitor multiple myeloma. Circulating plasma cells (CPCs) in peripheral blood are robust and independent prognostic markers, but their detection is challenging due to their low abundance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!