To develop an online plan adaptation algorithm for intensity modulated proton therapy (IMPT) based on fast Monte Carlo dose calculation and cone beam CT (CBCT) imaging. A cohort of ten head and neck cancer patients with an average of six CBCT scans were studied. To adapt the treatment plan to the new patient geometry, contours were propagated to the CBCTs with a vector field (VF) calculated with deformable image registration between the CT and the CBCTs. Within the adaptive planning algorithm, beamlets were shifted following the VF at their distal falloff and raytraced in the CBCT to adjust their energies, creating a geometrically adapted plan. Four geometric adaptation modes were studied: unconstrained geometric shifts (Free), isocenter shift (Iso), a range shifter (RS), or isocenter shift and range shifter (Iso-RS). After evaluation of the geometrical adaptation, the weights of a selected subset of beamlets were automatically tuned using MC-generated influence matrices to fulfill the original plan requirements. All beamlet calculations were done with a fast Monte Carlo running on a GPU (graphics processing unit). Geometrical adaptation alone only worked with small anatomy changes. The weight-tuned adaptation worked for every fraction, with the Free and Iso modes performing similarly and being superior than the two range shifters modes. The mean V95 and V107 were 99.4 ± 0.9 and 6.4% ± 4.7% in the Free mode with weight tuning. The calculation time per fraction was ~5 min, but further task parallelization could reduce it to ~1-2 min for delivery adaptation right after patient setup. An online adaptation algorithm was developed that significantly improved the treatment quality for inter-fractional geometry changes. Clinical implementation of the algorithm would allow delivery adaptation right before treatment and thus allow planning margin reductions for IMPT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/aaf30b | DOI Listing |
Indian J Nucl Med
November 2024
Center for Research and Production of Radioisotopes, Dalat Nuclear Research Institute, Vietnam Atomic Energy Institute (VINATOM), Da Lat City, Lam Dong Province, Vietnam.
Aims: This study aimed to evaluate the principal technical characteristics of a well-type gas-filled ionization chamber dose calibrator used in measuring radiopharmaceutical activity, namely accuracy, repeatability, and linearity. Furthermore, this work also explored the correlation between the device's response and the position and volume of the radiopharmaceutical I-131.
Materials And Methods: Experimental measurements were conducted on the ATOMLAB 500 dose calibrator using NIST traceable Cs-137 source to determine the accuracy and repeatability.
Sci Rep
January 2025
College of Safety Science and Engineering, Liaoning Technical University, Fuxin, 123000, Liaoning, China.
The abandoned coal in goaf will adsorb the gases ethylene (CH) and acetylene (CH) produced by coal oxidation, which makes the concentration data of the indicator gas inaccurate. Therefore, the adsorption law of coal and CH and CH gas is explored. The macromolecular structure model of coal was established and optimized by simulation, and the gas adsorption process was simulated by means of grand canonical Monte Carlo method.
View Article and Find Full Text PDFJ Phys Chem B
January 2025
Department of Chemical Engineering, IIT Gandhinagar, Gandhinagar, Gujarat 382055, India.
We compare the structures of polymer globules, composed of flexible polymer chains, with liquid droplets made of nonbonded monomers of the same polymer in poor solvents. This comparison is performed in three different poor solvents, with and without the addition of cosolvents. Molecular dynamics simulations are used to analyze the properties of the polymer globules, while semigrand canonical Monte Carlo simulations are used to form metastable liquid droplets of nonbonded monomers through homogeneous nucleation in the same solvents.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Radiation Oncology, Inha University Hospital, Incheon, Republic of Korea.
Background: High-dose-rate (HDR) brachytherapy using Iridium-192 as a radiation source is widely employed in cancer treatment to deliver concentrated radiation doses while minimizing normal tissue exposure. In this treatment, the precision with which the sealed radioisotope source is delivered significantly impacts clinical outcomes.
Purpose: This study aims to evaluate the feasibility of a new four-dimensional (4D) in vivo source tracking and treatment verification system for HDR brachytherapy using a patient-specific approach.
J Dairy Sci
January 2025
The Roslin Institute and Royal (Dick) School of Veterinary Studies, University of Edinburgh, Midlothian EH25 9RG, United Kingdom. Electronic address:
This study investigated the genetics of bovine tuberculosis (bTB) infectivity in Holstein-Friesian dairy cows using British national data. The analyses included cows with recorded sires from herds affected by bTB outbreaks between 2000 and 2022. Animals were considered bTB-positive if they reacted positively to the skin test and/or had positive post-mortem findings.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!