A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Photoplethysmography in dogs and cats: a selection of alternative measurement sites for a pet monitor. | LitMetric

Photoplethysmography in dogs and cats: a selection of alternative measurement sites for a pet monitor.

Physiol Meas

Biophotonics Laboratory, Institute of Atomic Physics and Spectroscopy, University of Latvia, 19 Raina Blvd., LV-1586, Riga, Latvia.

Published: January 2019

Objective: Photoplethysmography (PPG) is an increasingly popular health and well-being tool for monitoring heart rate and oxygen saturation. Due to the pigmentation and hairiness of dogs and cats, a pulse oximeter is routinely placed solely on the tongue. As this approach is feasible only for pet monitor use during surgical procedures, we investigate PPG signal quality on several other measurement sites that would be better tolerated by conscious animals.

Approach: Acquired PPG signals are analyzed by four signal quality indices: mean baseline, signal power, kurtosis, and tolerance score.

Main Results: In dogs, the metacarpus and tail can be substituted for oral pulse oximeter placement since both measurement sites exhibited high PPG signal kurtosis and were considered well-tolerated. In cats, the digit could be used with some limitations.

Significance: Pet monitors with pulse oximeter probes adjusted to promising measurement sites could enable veterinarians and owners to monitor animals when fully awake.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6579/aaf433DOI Listing

Publication Analysis

Top Keywords

measurement sites
16
pulse oximeter
12
dogs cats
8
pet monitor
8
ppg signal
8
signal quality
8
photoplethysmography dogs
4
cats selection
4
selection alternative
4
measurement
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!