Importance: Hospital outcomes for transcatheter aortic valve replacement (TAVR) may be dependent on the quality of evaluation, personnel, and procedural and postprocedural care common to patients undergoing cardiac surgery.

Objectives: We sought to assess whether those hospitals with better patient outcomes for surgical aortic valve replacement (SAVR) subsequently achieved better TAVR outcomes after launching TAVR programs.

Design, Setting, And Participants: This national cohort included US patients 65 years and older. The analysis used the Centers for Medicare and Medicaid Services' Medicare Provider and Review data collected between January 1, 2010, and September 29, 2015. Only hospitals performing at least 1 SAVR prior to September 1, 2011, and performing at least 1 TAVR after this date were included in the analysis. Data analysis was completed from June 2018 to August 2018.

Interventions: Isolated aortic valve replacements.

Main Outcomes And Measures: Hospital risk-adjusted 30-day mortality for SAVR in the pre-TAVR period was used as a surrogate for SAVR quality. Thirty-day and 1-year TAVR mortality rates were examined after stratification by quartile of baseline hospital risk-adjusted SAVR mortality.

Results: A total of 51 924 TAVR procedures were performed in 519 hospitals, of which 19 798 were performed at hospitals in quartile 1 (the lowest risk-adjusted SAVR mortality rate), 7663 were performed in quartile 2, 10 180 were performed in quartile 3, and 14 283 were performed in quartile 4 (the highest risk-adjusted SAVR mortality rate). Observed mortality rates at 30 days consistently increased with increasing baseline hospital SAVR risk-adjusted mortality (quartile 1, 917 patients [4.6%]; quartile 2, 381 [5.0%]; quartile 3, 521 [5.1%]; quartile 4, 800 [5.6%]; P < .001). The same pattern was observed in 1-year mortality (quartile 1, 3359 [17.0%]; quartile 2, 1337 [17.5%]; quartile 3, 1852 [18.2%]; quartile 4, 2652 [18.6%]; P < .001). After multivariable analysis, compared with the lowest quartile of SAVR mortality, undergoing TAVR at a hospital with higher baseline SAVR mortality continued to be associated with higher 30-day mortality (odds ratios: quartile 2, 1.02 [95% CI, 0.87-1.21]; quartile 3, 1.13 [95% CI, 1.02-1.26]; quartile 4, 1.23 [95% CI, 1.07-1.40]; P = .02) and 1-year mortality (hazard ratios: quartile 2, 1.04 [95% CI, 0.92-1.17]; quartile 3, 1.14 [95% CI, 1.02-1.28]; quartile 4, 1.16 [95% CI, 1.05-1.28]; P = .02).

Conclusions And Relevance: Hospitals with higher SAVR mortality rates also had higher short-term and long-term TAVR mortality after initiating TAVR programs. Quality of cardiac surgical care may be associated with a hospital's performance with new structural heart disease programs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6439689PMC
http://dx.doi.org/10.1001/jamacardio.2018.4051DOI Listing

Publication Analysis

Top Keywords

aortic valve
20
valve replacement
16
risk-adjusted savr
12
performed quartile
12
quartile
9
surgical aortic
8
transcatheter aortic
8
savr
8
hospital risk-adjusted
8
mortality rates
8

Similar Publications

Since the first transcatheter aortic valve replacement (TAVR) was performed in China in 2010, TAVR has developed rapidly. However, the temporal trends in the 1-year prognosis after TAVR in China have not been described. This study enrolled patients treated at a high-volume Chinese TAVR center, West China Hospital, between 2015 and 2022, to analyze and characterize the temporal trends in 1-year outcomes.

View Article and Find Full Text PDF

Percutaneous valve implantation or surgical replacement with mechanical or biological valves are standard therapies for severe valvular heart diseases. Prosthetic valve thrombosis, though rare, is a serious complication, particularly with mechanical prostheses. This study aimed to investigate the predictive value of platelet volume parameters, including mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR), for valvular thrombosis risk in patients undergoing valve replacement therapy.

View Article and Find Full Text PDF

Subvalvular aortic stenosis typically manifests at a young age and rarely presents in adulthood. It may cause left ventricular outflow tract stenosis, which requires surgical treatment in severe cases. The coexistence of discrete subvalvular aortic stenosis and quadricuspid aortic valve is a highly unusual finding.

View Article and Find Full Text PDF

The VACTERL (vertebral defects, anal atresia, cardiac defects, tracheoesophageal fistula, renal anomalies, and limb abnormalities) association represents an enigmatic syndrome requiring further study. This report describes a full-term neonate born to a multiparous woman who was found, upon further examination, to have multiple congenital abnormalities, including a bicuspid aortic valve, patent foramen ovale, tracheoesophageal fistula (TEF), asymmetric crying facies, microphallus, and a single inguinal testis. The discussion explores environmental and genetic factors that may contribute to this association, as well as similar conditions, such as CHARGE (coloboma, heart defects, choanal atresia, growth retardation, genital abnormalities, and ear abnormalities) syndrome.

View Article and Find Full Text PDF

The Y-incision aortic annular enlargement (AAE) has been established as a safe and effective technique for upsizing the aortic annulus by 3 to 4 valve sizes. However, concerns have been raised regarding its technical complexity during reoperations, particularly given the extensive enlargement of the aortic annulus and root. We present a case of reoperative aortic valve replacement after previous Y-incision AAE for prosthetic valve endocarditis and aortic root abscess.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!