The purpose of this study was to evaluate the hemodynamic properties and microemboli capture associated with different vacuum-assisted venous drainage (VAVD) vacuum levels and venous reservoir levels in a neonatal cardiopulmonary bypass circuit. Trials were conducted in 2 parallel circuits to compare the performance of Capiox Baby RX05 oxygenator with separate AF02 arterial filter to Capiox FX05 oxygenator with integrated arterial filter. Arterial cannula flow rate to the patient was held at 500 mL/min and temperature maintained at 32°C, while VAVD vacuum levels (0 mm Hg, -15 mm Hg, -30 mm Hg, -45 mm Hg, -60 mm Hg) and venous reservoir levels (50 mL, 200 mL) were evaluated in both oxygenators. Hemodynamic parameters measuring flow, pressure, and total hemodynamic energy were made in real time using a custom-made data acquisition system and Labview software. Nearly 10 cc bolus of air was injected into the venous line and gaseous microemboli detected using an Emboli Detection and Classification Quantifier. Diverted blood flow via the arterial filter's purge line and mean pressures increased with increasing VAVD levels (P < 0.01). Mean pressures were lower with lower venous reservoir levels and were greater in RX05 groups compared to FX05 (P < 0.01). Microemboli detected at the preoxygenator site increased with higher VAVD vacuum levels and lower venous reservoir levels (P < 0.01). The amount of microemboli captured by the FX05 oxygenator with integrated arterial filter was greater than by the RX05 oxygenator alone, although both oxygenators were able to clear microemboli before reaching the pseudo-patient.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aor.13404DOI Listing

Publication Analysis

Top Keywords

venous reservoir
12
capiox fx05
8
neonatal cardiopulmonary
8
cardiopulmonary bypass
8
vacuum-assisted venous
8
venous drainage
8
vavd vacuum
8
vacuum levels
8
reservoir levels
8
arterial filter
8

Similar Publications

Background: Bioresorbable scaffolds (BRS) were developed to overcome limitations related to late stent failures of drug-eluting stents, but lumen reductions over time after implantation of BRS have been reported. This study aimed to investigate if lesion preparation with a scoring balloon compared with a standard noncompliant balloon minimizes lumen reduction after implantation of a Magmaris BRS assessed with optical coherence tomography and intravascular ultrasound.

Methods: Eighty-two patients with stable angina were randomized in a ratio of 1:1 to lesion preparation with a scoring balloon versus a standard noncompliant balloon before implantation of a Magmaris BRS.

View Article and Find Full Text PDF

Introduction: Nicaragua is a Central American country with a high prevalence of patients with chronic kidney disease, particularly among young men. This is largely attributable to Mesoamerican nephropathy, a form of interstitial nephritis that predominantly affects young agricultural workers. While the majority of patients have access to chronic dialysis programs, a very small number have an option of receiving a renal transplant.

View Article and Find Full Text PDF

Importance: The current definition of central line-associated bloodstream infection (CLABSI) may overestimate the true incidence of CLABSI as it is often unclear whether the bloodstream infection (BSI) is secondary to the central line or due to another infectious source.

Objectives: We aimed to assess the prevalence and outcomes of central CLABSI at our institution, to identify opportunities for improvement, appropriately direct efforts for infection reduction, and identify gaps in the CLABSI definition and its application as a quality measure.

Design Setting And Participants: Retrospective cross-sectional study of patients identified to have a CLABSI in the period 2018-2022 cared for at the value-based purchasing (VBP) units of a 1200-bed tertiary care hospital located in Cleveland, OH.

View Article and Find Full Text PDF

Remote-Controlled and Teleoperated Systems: Taking Robotic Image Guided Interventions to the Next Stage.

Tech Vasc Interv Radiol

December 2024

Division of Vascular and Interventional Radiology, Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD. Electronic address:

Remote-controlled and teleoperated robotic systems mark transformative advancements in interventional radiology (IR), with the potential to enhance precision, reduce radiation exposure, and expand access to care. By integrating robotic devices with imaging guidance, these systems enable precise instrument placement and navigation, thereby improving the efficacy and safety of minimally invasive procedures. Remote-controlled and teleoperated robotic systems-operated by clinicians using control interfaces from within or adjacent to the procedure room-are being adopted for both percutaneous and endovascular interventions.

View Article and Find Full Text PDF

Background: Extracorporeal membrane oxygenation (ECMO) is a critical treatment for severe cardiopulmonary failure. However, traditional ECMO decannulation methods, such as manual compression and surgical repair, are associated with significant complications. This study evaluates suture-mediated closure devices, specifically Perclose ProGlide, as a potentially favorable decannulation strategy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!