Capacitively Coupled Phase-based Dielectric Spectroscopy Tomography.

Sci Rep

Engineering Tomography Laboratory (ETL), Department of Electronic and Electrical Engineering, University of Bath, Claverton Down, BA2 7AY, UK.

Published: December 2018

Impedance imaging is an effective approach for non-intrusively reconstruct the distribution of dielectric parameters inside the region of interest. Most common form of impedance imaging is electrical impedance tomography (EIT), which requires direct contact with the medium via electrodes. In this work we present a novel impedance imaging using capacitive coupling which provides a contactless method, totally non-invasive and non-intrusive, by measuring the phase. There are less attentions in many prior works to the phase information of the voltage/current measurements. This work studies for the first time the capacitively coupled electrical phase spectroscopy for contactless dielectric parameter imaging. A 12-electrode capacitively coupled test phantom and a measurement system were used to obtain the phase measurements within a wideband frequency range from 200 kHz to 15 MHz. Background data with different conductivity levels were investigated in the experiments to show a broad application possibility. The forward modelling was implemented by simulation and the image reconstruction based on phase measurements was implemented with the total variation algorithm. The potentials, possibilities and challenges of such capacitively coupled dielectric spectroscopy tomography with phase data are discussed in this work.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6277455PMC
http://dx.doi.org/10.1038/s41598-018-35904-4DOI Listing

Publication Analysis

Top Keywords

capacitively coupled
16
impedance imaging
12
dielectric spectroscopy
8
spectroscopy tomography
8
phase measurements
8
phase
6
capacitively
4
coupled phase-based
4
dielectric
4
phase-based dielectric
4

Similar Publications

A 35 nV/√Hz Analog Front-End Circuit with Adjustable Bandwidth and Gain in UMC 40 nm CMOS for Biopotential Signal Acquisition.

Sensors (Basel)

December 2024

State Key Discipline Laboratory of Wide Bandgap Semiconductor Technology, School of Microelectronics, Xidian University, Xi'an 710071, China.

This paper presents a 35 nV/√Hz analog front-end (AFE) circuitdesigned in the UMC 40 nm CMOS technology for the acquisition of biopotential signal. The proposed AFE consists of a capacitive-coupled instrumentation amplifier (CCIA) and a combination of a programmable gain amplifier (PGA) and a low-pass filter (LPF). The CCIA includes a DC servo loop (DSL) to eliminate electrode DC offset (EDO) and a ripple rejection loop (RRL) with self-zeroing technology to suppress high-frequency ripples caused by the chopper.

View Article and Find Full Text PDF

Deformation-Induced Electromagnetic Reconfigurable Square Ring Kirigami Metasurfaces.

Micromachines (Basel)

December 2024

Tianmushan Laboratory, Yuhang District, Hangzhou 311115, China.

The continuous expansion of wireless communication application scenarios demands the active tuning of electromagnetic (EM) metamaterials, which is essential for their flexible adaptation to complex EM environments. However, EM reconfigurable systems based on intricate designs and smart materials often exhibit limited flexibility and incur high manufacturing costs. Inspired by mechanical metastructures capable of switching between multistable configurations under repeated deformation, we propose a planar kirigami frequency selective surface (FSS) that enables mechanical control of its resonant frequency.

View Article and Find Full Text PDF

This paper introduces a novel contactless single-chip detector that utilizes impedance-to-digital conversion technology to measure impedance in the microfluidic channel or capillary format analytical device. The detector is designed to operate similarly to capacitively coupled contactless conductivity detectors for capillary electrophoresis or chromatography but with the added capability of performing frequency sweeps up to 200 kHz. At each recorded data point, impedance and phase-shift data can be extracted, which can be used to generate impedance versus frequency plots, or phase-shift versus frequency plots.

View Article and Find Full Text PDF

Fibrotic cardiomyopathy represents a significant pathological condition characterized by the interaction between cardiomyocytes and fibroblasts in the heart, and it currently lacks an effective cure. In vitro platforms, such as engineered heart tissue (EHT) developed through the co-culturing of cardiomyocytes and fibroblasts, are under investigation to elucidate and manipulate these cellular interactions. We present the first integration of mathematical electrophysiological models that encapsulate fibroblast-cardiomyocyte interactions with experimental EHT studies to identify and modulate the ion channels governing these dynamics.

View Article and Find Full Text PDF

Characterized by their high sensitivity and flexible deformation, flexible pressure sensors have been extensively applied in various fields such as wearable electronics, health monitoring, soft robotics, and human-computer interaction. In this research, we developed a dual-response pressure sensor (DRPS) designed to identify object materials. By integrating the operating principles of capacitive and resistive sensors and employing microstructured dielectric layers, we enhanced the sensitivity and detection range of the pressure sensor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!