Acute ischemic stroke (AIS) is a major complication in left ventricular assist device (LVAD) population. A better understanding of clinical risk factors associated with AIS may help mitigate risk of stroke. We reviewed prospectively collected data of 477 LVAD patients from a tertiary center from October 1, 2004 to December 31, 2016. Supplemental data abstraction was performed on patients with AIS. Fifty-seven (12%) developed 61 AIS. Of 61, 17 (28%) AIS occurred perioperatively. The median time from implant to perioperative AIS was 5 days (interquartile range: 3-9). Pump thrombosis accounted for 19 (31%) of 61 AIS, and 7 (37%) presented initially with AIS before the pump thrombosis. The median lactate dehydrogenase (LDH) at the time of AIS in the pump thrombosis group (806) was higher than LDH at 1 month (437, P = 0.27) at 3 months (334, P = 0.01), and 6 months (286, P = 0.001) before AIS. Thirty-three (54%) AIS occurred while receiving inadequate antithrombotic therapy. Acute infections were common (31, 51%) in AIS and 12 (20%) were associated with acute bloodstream infection. All AIS were explained by a combination of four clinical risk factors. All LVAD-associated AIS occurred perioperatively or in conjunction with pump thrombosis, subtherapeutic anticoagulation, and bloodstream infection. The common underlying thread is occurrence of a prothrombotic state. The results of this study underscore the potential consequences of disruption of delicate hemostatic balance in patients with LVAD.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAT.0000000000000901DOI Listing

Publication Analysis

Top Keywords

pump thrombosis
20
ais
14
ais occurred
12
clinical risk
8
risk factors
8
occurred perioperatively
8
ais pump
8
bloodstream infection
8
pump
5
thrombosis
5

Similar Publications

Background: Prior analyses have suggested that a smaller left ventricular end-diastolic diameter (LVEDD) is associated with reduced survival following HeartMate 3 left ventricular assist device implantation.

Objectives: In this trial-based comprehensive analysis, the authors sought to examine clinical characteristics and association with the outcome of this specific relationship.

Methods: The authors analyzed the presence of LVEDD <55 mm among 1,921 analyzable HeartMate 3 patients within the MOMENTUM 3 (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) trial portfolio, on endpoints of overall survival and adverse events at 2 years.

View Article and Find Full Text PDF

: Patients with a HeartMate 3 (HM3) left ventricular assist device (LVAD) typically receive anticoagulation and antiplatelet therapy. The HM3 has shown a marked reduction in hemocompatibility-related adverse events (HRAEs) like stroke, bleeding, and pump thrombosis. This study evaluated whether aspirin (ASA) response influences HRAE incidence and if ASA sensitivity changes over time in HM3 recipients.

View Article and Find Full Text PDF

Background: Initially conceptualized as a bridge to heart transplantation, the left ventricular assist device (LVAD) has become an important option for improving survival in patients with severe heart failure and poor prognosis.

Case Summary: We report the case of a patient suffering from severe chronic heart failure, complicated by ST-elevation myocardial infarction due to left main coronary artery stenosis (NYHA IV, INTERMACS profile 1). Despite support with veno-arterial extracorporeal membrane oxygenation, inotropes, and catecholamine therapy, the patient's cardiac function did not recover sufficiently.

View Article and Find Full Text PDF

Background: Impella RP and RP Flex can provide right ventricular (RV) support in numerous clinical situations. Notably, the redesigned RP Flex allows for an internal jugular approach compared to the femoral venous approach with RP.

Aims: We investigated the type and frequency of device-related complications as reported in the US Food and Drug Administration (FDA) Manufacturer and User Facility Experience (MAUDE) for both Impella RP and RP Flex to see if there are any differences.

View Article and Find Full Text PDF

Background: Subaortic pannus formation complicates bioprosthetic aortic valve (AV) replacement. We report an extreme case in a continuous-flow left ventricular assist device (LVAD) patient.

Case Summary: A 49-year-old Caucasian female with dilated cardiomyopathy was bridged to transplant with a HeartWare Ventricular Assist Device (Medtronic).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?