The detection and analysis of rare blood biomarkers is necessary for early diagnosis of cancer and to facilitate the development of tailored therapies. However, current methods for the isolation of circulating tumour cells (CTCs) or nucleic acids present in a standard clinical sample of only 5-10 ml of blood provide inadequate yields for early cancer detection and comprehensive molecular profiling. Here, we report the development of a flexible magnetic wire that can retrieve rare biomarkers from the subject's blood in vivo at a much higher yield. The wire is inserted and removed through a standard intravenous catheter and captures biomarkers that have been previously labelled with injected magnetic particles. In a proof-of-concept experiment in a live porcine model, we demonstrate the in vivo labelling and single-pass capture of viable model CTCs in less than 10 s. The wire achieves capture efficiencies that correspond to enrichments of 10-80 times the amount of CTCs in a 5-ml blood draw, and 500-5,000 times the enrichments achieved using the commercially available Gilupi CellCollector.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6261517PMC
http://dx.doi.org/10.1038/s41551-018-0257-3DOI Listing

Publication Analysis

Top Keywords

magnetic wire
8
circulating tumour
8
tumour cells
8
intravascular magnetic
4
wire
4
wire high-throughput
4
high-throughput retrieval
4
retrieval circulating
4
cells vivo
4
vivo detection
4

Similar Publications

Reducing Disorder in PbTe Nanowires for Majorana Research.

Nano Lett

January 2025

State Key Laboratory of Low Dimensional Quantum Physics, Department of Physics, Tsinghua University, Beijing 100084, China.

Material challenges are the key issue in Majorana research, where surface disorder constrains device performance. Here, we tackle this challenge by embedding PbTe nanowires within a lattice-constant-matched crystal. The wire edges are shaped by self-organized growth instead of lithography, resulting in nearly atomically flat facets along both cross-sectional and longitudinal directions.

View Article and Find Full Text PDF

Venous Endothelial Cell Transcriptomic Profiling Implicates METAP1 in Preeclampsia.

Circ Res

December 2024

Cardiovascular Research Center, Massachusetts General Hospital, Boston. (C.C., P.X., Z.Y., Y.S., E.S.L., J.D.R., M.C.H.).

Background: Preeclampsia is a hypertensive disorder of pregnancy characterized by systemic endothelial dysfunction. The pathophysiology of preeclampsia remains incompletely understood. This study used human venous endothelial cell (EC) transcriptional profiling to investigate potential novel mechanisms underlying EC dysfunction in preeclampsia.

View Article and Find Full Text PDF

Background: T thermometry is considered a straight method for the safety monitoring of patients with deep brain stimulation (DBS) electrodes against radiofrequency-induced heating during Magnetic Resonance Imaging (MRI), requiring different sequences and methods.

Objective: This study aimed to compare two T thermometry methods and two low specific absorption rate (SAR) imaging sequences in terms of the output image quality.

Material And Methods: In this experimental study, a gel phantom was prepared, resembling the brain tissue properties with a copper wire inside.

View Article and Find Full Text PDF

An examination of cortical thickness relationships within the reading network of adults.

Brain Struct Funct

December 2024

Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, T6G 2G4, Canada.

Much brain imaging work has underscored the functional connections among the inferior frontal gyrus (IFG; articulation), supramarginal gyrus (SMG; letter-sound correspondence), superior temporal gyrus (STG; sound) and fusiform gyrus (FFG; print) during basic reading processes. This reading network supports and coordinates the complex processes that contribute to successful reading. In line with the Hebbian notion that 'neurons that fire together, wire together' we examined cortical thickness among these regions and the extent to which these regions showed structural relationships in average and impaired readers.

View Article and Find Full Text PDF

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!