Background: Prolonged alveolar air leak (PAL) is the most common adverse event following pulmonary resection. It carries morbidity for patients by increasing empyema risk, and for hospital administration with the cost of prolonged length of hospital stay (LOS). Intra-operative sealant technology is available to surgeons, and may decrease PAL. Our aim was to conduct a systematic review and meta-analysis of randomized controlled trials (RCTs) on the effect of intraoperative polymeric sealant use on PAL, empyema, and LOS.
Methods: Standard PRISMA (Preferred Reporting Items for Systematic reviews and Meta-analysis and methods) protocol was adhered to. For qualitative review the search strategy yielded 21 RCTs reporting polymeric sealant use in lung resection, 19 of which were included in meta-analyses. The control arm in the two excluded RCTs was not "standard care." Random-effects meta-analyses were conducted. Inter-trial heterogeneity was assessed with the I2 statistic. Publication bias was assessed with a funnel plot and Egger statistic for small study effects.
Results: Pooled analysis was derived from 2,537 randomized participants. They were allocated to the intervention arm of lung resection with intra-operative application of a polymeric sealant (n=1,292), or the control arm of standard care involving pulmonary resection with pneumostasis by sutures and/or stapler (n=1,245). Participants came from 10 different countries, with mean (SD) age of 62.5 (4.2) years, and 31.6% (95% CI: 30.0-33.5) female. Pooled estimates revealed polymeric sealant decreased odds of PAL (OR 0.55, 95% CI: 0.35-0.87), and decreased LOS by one day (mean difference -0.96, 95% CI: -1.74 to -0.18), without increasing odds of pleural sepsis (OR 1.134, 95% CI: 0.343-3.748). There was evidence of publication bias in the LOS meta-analysis.
Conclusions: Pooled analysis revealed decreased odds of PAL, and decreased LOS by one day with intraoperative use of polymeric sealants. There was no associated increase in odds of adverse events, including empyema.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6258656 | PMC |
http://dx.doi.org/10.21037/jtd.2018.10.48 | DOI Listing |
Purpose: To make micro-CT comparison and evaluation of sealant penetration depth in different types of fissures after heating of the material or application of vibrations.
Materials And Methods: One hundred sound third molars have been sealed as follows: group 1 (n = 20), light-cured resin sealant at room temperature, group 2 (n = 20), light-cured resin sealant, preheated to 41.0°C, group 3 (n = 20), light-cured resin sealant, preheated to 51.
Polymers (Basel)
January 2025
Department of Mechanical, Chemical, and Materials Engineering, University of Cagliari, Via Marengo 2, 09123 Cagliari, CA, Italy.
Starch is among the most abundant natural compounds in nature after cellulose. Studies have shown that the structure and functions of starch differ extensively across and among botanical types, isolation procedures, and climate factors, resulting in starch with significant variations in its chemical, physical, morphological, thermal, and functional characteristics. To enhance its beneficial properties and address inherent limitations, starch is modified through various techniques, resulting in significant alterations to its chemical and physical characteristics.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, China.
Powder-based hemostatic materials have offered unprecedented opportunities for the effective sealing and repair of irregularly shaped wounds and high-pressure, noncompressible arterial bleeding wounds caused by surgeries, traffic accidents, and wartime injuries. However, inadequate adhesion to bleeding wounds and poor hemostasis in biological tissues remains challenging. Herein, we report a self-gelling hemostatic powder based on polyacrylic acid/polyethyleneimine/polyethylene glycol (named PPG) for rapid hemostasis and effective antibacterial ability.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
Department of Innovation Engineering, Ukrainian State University of Science and Technologies, 2 Lazariana Avenue, 49000 Dnipro, Ukraine.
The current research is devoted to integrating naturally renewable cardanol derivatives into one-component silyl-terminated-polyether-based prepolymer systems to improve climatic resistance and obtain materials with versatile mechanical properties that could be significant to various sectors of the economy. Various cardanol-type products are used in industries that require high climatic resistance, and thus combining cardanol with commercially available silyl-terminated polyether prepolymers would improve its material climatic resistance, maintaining its market and application value as well as improving material sustainability. The results obtained in this work show that depending on how the cardanol prepolymer Ultra Lite 513 is modified, it is possible to increase the elasticity (670%) or tensile strength (104%) of the material as well as significantly increase the climatic resistance of the material, thus improving the quality and sustainability of the adhesive compared to existing silyl-terminated-prepolymer-based adhesives on the market.
View Article and Find Full Text PDFOper Dent
January 2025
*Roberta Tarkany Basting, DDS, MSc, PhD, Professor, Restorative Dentistry Department, Faculdade São Leopoldo Mandic, São Paulo, Brazil.
This study evaluated the influence of six resin composite coating agents on color stability and surface roughness after toothbrushing abrasion. Discs (Ø6 mm x 2 mm) of nanofilled resin composite (Filtek Z350XT) were prepared for application of coating agents (n=10): control (absence), two surface sealants (PermaSeal and BisCover LV), two adhesive systems (Scotchbond Multi-Purpose Adhesive/3M Oral Care and Single Bond Universal), and two modeling liquids (Modeling Resin and Composite Wetting Resin). CIELab*, WID, and color change (ΔEab, ΔE00, and ΔWID) were analyzed at baseline, after finishing and polishing, after application of coating agents, after coffee staining (simulating 30 days and one year of staining), and after toothbrushing abrasion.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!