Background: Transverse process fractures in trauma patients frequently are diagnosed using computed tomography and result in severe pain and limitation of motion. However, there is no accepted standard of care. Thus, these fractures can be treated with excessive measures or inadequately treated. In this study, diagnosis and treatment of transverse process fractures are examined.
Methods: The mechanisms of trauma, findings, and associated organ injuries of 50 patients with transverse process fractures and no other spinal injuries treated between 2013 and 2015 were recorded. The same treatment protocol was applied to each patient. The results of the treatments were examined retrospectively and recorded.
Results: Deformation and edema of the fascia and muscles around the transverse process fractures were detected by computed tomography and magnetic resonance imaging. The average pain intensity of the patients before treatment was 8.8 of 10 on a visual analog scale and 5.2 of 10 after treatment with nonsteroidal anti-inflammatory drugs, muscle relaxants, flexible support corsets, and mobilization. Patients hospitalized for additional pathologies were primarily treated in thoracic surgery wards (11 of 15 patients). Transverse process fractures were caused by backward falls or blows to the back in 49 patients.
Conclusions: Transverse process fractures can be treated quickly and effectively with the recommended protocol after excluding any accompanying organ injuries or other spinal injuries. Transverse process fractures most often occur during backward falls or blows to the back, commonly low-energy injuries. This trauma mechanism can be described as a "coronal injury of the spine."
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.wneu.2018.11.147 | DOI Listing |
BMC Med Imaging
December 2024
Department of Radiology, School of Medicine, University of Health and Allied Sciences (UHAS), Ho, Ghana.
Background: Microcardia and cardiomegaly are good diagnostic and prognostic tools for several diseases. This study investigated the distribution of microcardia and cardiomegaly among students of the University of Health and Allied Sciences (UHAS) in Ghana to determine the prevalence of microcardia and cardiomegaly across gender, and to evaluate the correlation between the presence of these heart conditions and age.
Methods: This retrospective study involved a review of 4519 postero-anterior (PA) chest X-rays (CXRs) between 2020 and 2023.
Sci Rep
December 2024
College of Mechanical and Electrical Engineering, Wenzhou University, Wenzhou, 325035, China.
As a critical component of aero-engines, the processing quality of the blade has a significant impact on the engine's overall performance and service life. First, from the perspective of double abrasive grains, two finite element models-simultaneous and sequential scratches-are established. The interaction between the two abrasive grains affects not only the polishing force and chip formation but also the surface morphology of the processed workpiece.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
December 2024
Aix Marseille Université, Université Gustave Eiffel, LBA, Marseille, France. Electronic address:
This study proposes a method for assessing the transverse toughness of human long-bone cortical tissue. The method is based on a three-point bending test of pre-notched femur diaphysis segments, post-processed using the compliance method coupled with numerical simulations. Given the cracking nature of bone and if cracking processes remain confined to the crack tip, it is assumed that the compliance method can be used.
View Article and Find Full Text PDFNeuroSci
December 2024
Laboratory of Surgical Neuroanatomy (LSNA), Human Anatomy and Embryology Unit, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08036 Barcelona, Spain.
Cauda equina nerve roots may become damaged during neuraxial anesthesia, and post-puncture headache may appear in the case of cerebrospinal fluid leakage if needle tips are deformed due to bone contact when several attempts are needed. Our aim was to verify the correlation between skin-transverse process distance (st) and skin-dural sac distance (d) for calculation of optimal angles in a free visual guide and as a reference for the maximal depth to be traversed by the needle. Randomly selected ex vivo samples ( = 10) were flexed to reproduce the position of the lumbosacral spine during spinal anesthesia.
View Article and Find Full Text PDFHeliyon
December 2024
Department of Mechanical, Chemical and Material Engineering, University of Cagliari, Via Marengo 2, 09123, Cagliari, Italy.
This study investigates the effects of heat treatment, involving solubilization and aging, on the microstructure of AA2017-T451 aluminum alloy. Samples of 4 mm thick rolled plate of AA2017 underwent solution treatment at 500 °C for two different durations, namely 2 h and 6 h, followed by either water quenching (WQ) or air quenching (AQ). Subsequently, they were artificially aged (AA) at 175 °C for 8 h.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!