Management of recurrent intracranial aneurysms after coil embolization: a novel classification scheme based on angiography.

J Neurosurg

1Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University; China National Clinical Research Center for Neurological Diseases; Center of Stroke, Beijing Institute for Brain Disorders; and Beijing Key Laboratory of Translational Medicine for Cerebrovascular Disease, Beijing; and.

Published: November 2019

Objective: Recurrent aneurysms after coil embolization remain a challenging issue. The goal of the present study was to report the authors' experience with recurrent aneurysms after coil embolization and to discuss the radiographic classification scheme and recommended management strategy.

Methods: Aneurysm treatments from a single institution over a 6-year period were retrospectively reviewed. Ninety-seven aneurysms that recurred after initial coiling were managed during the study period. Recurrent aneurysms were classified into the following 5 types based on their angiographic characteristics: I, pure recanalization inside the aneurysm sac; II, pure coil compaction without aneurysm growth; III, new aneurysm neck formed without coil compaction; IV, new aneurysm neck formed with coil compaction; and V, newly formed aneurysm neck and sac.

Results: Aneurysm recurrences resulted in rehemorrhages in 6 cases (6.2%) of type III-V aneurysms, but in none of type I-II aneurysms. There was a significantly higher proportion of ophthalmic artery aneurysms and complex internal carotid artery aneurysms presenting as types I and II than presented as the other 3 types (63.3% vs 16.4%, p < 0.001). In contrast, for posterior communicating artery aneurysms and anterior communicating artery aneurysms, a higher proportion of type III-V aneurysms was observed than for the other 2 types, but without a significant difference in the multivariate model (56.7% vs 23.3%). In addition, giant (> 25 mm) aneurysms were more common among type I and II lesions than among type III and IV aneurysms (36.7% vs 9.0%, p = 0.001), which exhibited a higher proportion of small (< 10 mm) lesions (65.7% vs 13.3%, p < 0.001). A single reembolization procedure was sufficient to occlude 80.0% of type I recurrences and 83.3% of type II recurrences from coil compaction but only 65.6% of type III-V recurrences from aneurysm regrowth.

Conclusions: Aneurysm size and location represent the determining factors of the angiographic recurrence types. Type I and II recurrences were safely treated by reembolization, whereas type III-V recurrences may be best managed surgically when technically feasible.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2018.6.JNS181046DOI Listing

Publication Analysis

Top Keywords

coil compaction
16
type iii-v
16
artery aneurysms
16
aneurysms
14
aneurysms coil
12
coil embolization
12
recurrent aneurysms
12
aneurysm neck
12
higher proportion
12
type recurrences
12

Similar Publications

Development of Novel Oral Delivery Systems Using Additive Manufacturing Technologies to Overcome Biopharmaceutical Challenges for Future Targeted Drug Delivery.

Pharmaceutics

December 2024

Department of Biopharmaceutics and Pharmaceutical Technology, Institute of Pharmacy, University of Greifswald, Felix-Hausdorff-Strasse 3, 17489 Greifswald, Germany.

The development of targeted drug delivery systems for active pharmaceutical ingredients with narrow absorption windows is crucial for improving their bioavailability. This study proposes a novel 3D-printed expandable drug delivery system designed to precisely administer drugs to the upper small intestine, where absorption is most efficient. The aim was to design, prototype, and evaluate the system's functionality for organ retention and targeted drug release.

View Article and Find Full Text PDF

We test here the prediction capabilities of the new generation of deep learning predictors in the more challenging situation of multistate multidomain proteins by using as a case study a coiled-coil family of Nucleotide-binding Oligomerization Domain-like (NOD-like) receptors from and a few extra examples for reference. Results reveal a truly remarkable ability of these platforms to correctly predict the 3D structure of modules that fold in well-established topologies. A lower performance is noticed in modeling morphing regions of these proteins, such as the coiled coils.

View Article and Find Full Text PDF

The Effect of CaCl on the Gelling Properties of Pea Protein-Pectin Dispersions.

Gels

December 2024

Department of Food Science and Technology, The Ohio State University, 2015 Fyffe Rd., Columbus, OH 43210, USA.

The effects of CaCl addition before (PreCa) or after (PostCa) heating pea protein-pectin dispersions on the formed gel's rheological and microstructural properties were investigated. Isothermal titration calorimetry (ITC) revealed that CaCl bound both pea proteins and pectins through a spontaneous exothermic reaction and pectin exhibited a stronger binding affinity to CaCl. In PreCa gels, low levels of CaCl (5 and 10 mM) increased the gel elasticity (increase in the storage modulus, G') and their microstructural compactness.

View Article and Find Full Text PDF

Coil embolization of cerebral aneurysms often encounters challenges in achieving complete filling of the aneurysm sac due to complex shapes and hemodynamic factors, frequently resulting in the formation of a residual cavity (RC) at the aneurysm neck. The hemodynamic mechanisms underlying RC formation and growth, however, remain poorly understood. Computational fluid dynamics (CFD) analysis, combined with silent MRA free from contrast agents and metal artifacts, offers a promising approach to elucidate these mechanisms, potentially enhancing the clinical management of cerebral aneurysms post-coiling.

View Article and Find Full Text PDF

Multi-layer conductive structures, especially those with features like bolt holes, are vulnerable to hidden corrosion and cracking, posing a serious threat to equipment integrity. Early defect detection is vital for implementing effective maintenance strategies. However, the subtle signals produced by these defects necessitate highly sensitive non-destructive testing (NDT) techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!