AI Article Synopsis

  • A study aimed to reduce pulmonary embolism (PE) rates in orthopaedic trauma patients by implementing a new protocol at a Level 1 trauma center.
  • The protocol involved assessing PE risk upon arrival, administering enoxaparin (a blood thinner) if possible, and using inferior vena cava filters when needed to prevent clots.
  • Results showed a decrease in PE cases from 2015 to 2016, with the incidence dropping significantly, indicating the protocol's effectiveness in high-risk patients.

Article Abstract

Objectives: To report results of a protocol to lessen incidence of pulmonary embolism (PE) among orthopaedic trauma patients.

Design: Retrospective review.

Setting: Level 1 trauma center.

Patient/participants: Orthopaedic trauma inpatients were included in the study.

Intervention: On arrival, an orthopaedic trauma patient's PE risk is calculated using a previously developed tool. If possible, patients at high risk are given their first dose of enoxaparin before leaving the emergency room. If other injuries preclude enoxaparin, then chemoprophylaxis is held for 24 hours. Twenty-four hours after arrival, the patient's ability to receive enoxaparin is reassessed. If possible, enoxaparin is started, with dosing twice a day. If enoxaparin is still contraindicated, a removable inferior vena cava filter is placed. Adequacy of enoxaparin dosing is tested using anti-factor Xa assay, drawn 4 hours after the third dose of enoxaparin. If the anti-factor Xa result is less than 0.2 IU/mL, a removable inferior vena cava filter is placed. If the result is 0.2-0.5 IU/mL, enoxaparin dosing is continued. If greater than 0.5 IU/mL, the dose of enoxaparin is reduced.

Outcome Measure: The main outcome measure was rate of PE.

Results: From September 1, 2015 to December 31, 2015, our hospital admitted 420 orthopaedic trauma patients. Fifty-one patients were classed as high risk for PE. In September through December 2015, 9 sustained PE, 1 of which was fatal. From September 1, 2016 to December 31, 2016, our hospital admitted 368 orthopaedic trauma patients with comparable age and Injury Severity Score to 2015. Forty patients were at high risk for PE, 1 sustained a nonfatal PE. PE incidence from September to December 2016 was significantly lower than in 2015 (P = 0.02). Overall, 26 patients managed under the new protocol had IVCFs placed, 21 had their filters removed, and 3 died with filters in place. There were no complications during filter placement or removal. One patient had hemorrhage felt to be attributable to enoxaparin.

Conclusions: Our protocol emphasizes more robust enoxaparin dosing, and more frequent use of IVCF, but only among those at high risk. We lessened the incidence of PE, with a low complication rate.

Level Of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BOT.0000000000001346DOI Listing

Publication Analysis

Top Keywords

orthopaedic trauma
24
high risk
16
trauma patients
12
dose enoxaparin
12
enoxaparin dosing
12
enoxaparin
10
pulmonary embolism
8
embolism orthopaedic
8
patients high
8
removable inferior
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!