A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of the caregiver effective dose during I-131 therapy of thyroid. | LitMetric

Analysis of the caregiver effective dose during I-131 therapy of thyroid.

J Cancer Res Ther

Department of Medical Radiation, Engineering Faculty, Central Tehran Branch, Islamic Azad University, Tehran, Iran.

Published: February 2019

Aims: The main objective of the present research is to analyze the caregiver effective dose during I-131 therapy of thyroid in some different situations using MCNP4C Monte Carlo code.

Patients And Methods: Two separate whole body Medical Internal Radiation Dosimetry (MIRD) phantoms have been defined simultaneously in a single Monte Carlo N-Particle (MCNP) input file as the patient and the caregiver. Two different groups of irradiation situations have been assumed for the caregiver related to the patient, (1) both the patient and the caregiver are standing and (2) the patient is lying in the bed while the caregiver is standing beside the patient.

Results: The results show that the caregiver effective dose is highly dependent on the position of the caregiver related to the patient. When the patient is lying on the bed and the caregiver is standing beside the patient near the head of the patient, the effective dose of caregiver will be the maximum value.

Conclusions: Although the maximum effective dose (0.2 mSv) is smaller than the allowed value for caregivers (5 mSv for each treatment), the final results of this research indicate the importance of caregiver position in close contact with the patient.

Download full-text PDF

Source
http://dx.doi.org/10.4103/0973-1482.199382DOI Listing

Publication Analysis

Top Keywords

effective dose
20
caregiver effective
12
caregiver standing
12
caregiver
10
patient
9
dose i-131
8
i-131 therapy
8
therapy thyroid
8
monte carlo
8
patient caregiver
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!