Here, a soft robotic microgripper is presented that consists of a smart actuated microgel connected to a spatially photopatterned multifunctional base. When pressed onto a target object, the microgel component conforms to its shape, thus providing a simple and adaptive solution for versatile micromanipulation. Without the need for active visual or force feedback, objects of widely varying mechanical and surface properties are reliably gripped through a combination of geometrical interlocking mechanisms instantiated by reversible shape-memory and thermal responsive swelling of the microgel. The gripper applies holding forces exceeding 400 µN, which is high enough to lift loads 1000 times heavier than the microgel. An untethered version of the gripper is developed by remotely controlling the position using magnetic actuation and the contractile state of the microgel using plasmonic absorption. Gentle yet stable robotic manipulation of biological samples under physiological conditions opens up possibilities for high-throughput interrogation and minimally invasive interventions.

Download full-text PDF

Source
http://dx.doi.org/10.1002/smll.201803870DOI Listing

Publication Analysis

Top Keywords

soft robotic
8
robotic microgripper
8
microgel
5
universal soft
4
microgripper soft
4
microgripper presented
4
presented consists
4
consists smart
4
smart actuated
4
actuated microgel
4

Similar Publications

Although the Transformer architecture has established itself as the industry standard for jobs involving natural language processing, it still has few uses in computer vision. In vision, attention is used in conjunction with convolutional networks or to replace individual convolutional network elements while preserving the overall network design. Differences between the two domains, such as significant variations in the scale of visual things and the higher granularity of pixels in images compared to words in the text, make it difficult to transfer Transformer from language to vision.

View Article and Find Full Text PDF

Background: Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control.

View Article and Find Full Text PDF

Is the Coronal Plane Alignment of the Knee (CPAK) Classification Useful to Plan Individualized Total Knee Arthroplasty Surgery for the Spanish Population? A Critical Analysis of the CPAK Classification.

Rev Esp Cir Ortop Traumatol

January 2025

Knee Surgery Unit, iMove Traumatology, Barcelona, Spain; Knee Surgery Unit, Orthopaedic Surgery Department, Hospital Sant Joan de Déu de Manresa - Fundació Althaia, Universitat de Vic, Manresa, Spain.

Introduction: The CPAK classification aims to categorize knee phenotypes. The original study was based on Australian and Belgian population, but significant variation in CPAK distribution exists between different geographic areas. The primary objective is to evaluate knee phenotypes of osteoarthritic Spanish population based on the CPAK system.

View Article and Find Full Text PDF

Electrochemical impedance spectroscopy has great potential for laboratory blood tests. The overall aim of this study is to develop a microfluidic sensor for determining the physical properties and hematological parameters of blood based on its dielectric spectra. Impedance was measured in flowing blood to prevent aggregation and sedimentation at frequencies between 40 Hz and 110 MHz.

View Article and Find Full Text PDF

Purpose: The adoption of robotic-assisted total hip arthroplasty (THA) is increasingly widespread, yet its influence on outcomes in outpatient surgery remains uncertain. This study aimed to evaluate whether robotic assistance reduces the rate of 90-day postoperative events in patients undergoing outpatient THA, compared to those in inpatient procedures.

Methods: This historical-prospective cohort study analyzed 706 primary THA cases performed between January 2017 and January 2023 by three senior surgeons.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!