Background: Obesity and the state of being overweight are increasing steadily and becoming a global epidemic. Recent research reports 64% of the adult population as overweight in Europe and the USA. The social and economic impacts are increasing, and most of the rehabilitation programs, while effective in the short term, do not produce long-lasting results. An explanatory model from a behavioral perspective can describe the phenomena with the lack of sources of reinforcement related to healthful habits in a daily life context.
Methods/design: A randomized clinical trial combining single-subject studies and a four-arm group design will be conducted to compare the effect of the current standard in obesity treatment to Acceptance and Commitment Therapy (ACT) and wearable technology at different times, before starting intervention, at the end, and at follow-up visits of 3, 6, and 12 months measuring changes over time of physical activity and psychological well-being.
Discussion: The goal of this project, combining ACT and wearable technology, is to develop an effective intervention, efficient and sustainable, which even after discharge can provide adequate contingencies of reinforcement in the natural environment, integrating systematic measurements, continuous feedback, and individualized, values-based objectives. The intervention is aimed to provide a contingent reinforcement for healthful behaviors instead of reinforcing only the achievement of a significant weight loss. The aim of the project, combining Acceptance and Commitment Therapy and Wearable Technology, is to develop an effective, efficient and sustainable intervention able to provide a contingent reinforcement for healthy behaviors. The intervention is aimed to promote adequate healthy behaviors in the natural environment, integrating systematic measurements, continuous feedback and individualized values-based objectives, instead of reinforcing only the achievement of a significant weight loss.
Trial Registration: ClinicalTrials.gov, NCT03351712 . Registered on 24 November 2017.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6262958 | PMC |
http://dx.doi.org/10.1186/s13063-018-2968-x | DOI Listing |
ACS Sens
January 2025
CAS Key Laboratory of Magnetic Materials and Devices, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, P. R. China.
Flexible pressure sensors are pivotal in advancing artificial intelligence, the Internet of Things (IoT), and wearable technologies. While microstructuring the functional layer of these sensors effectively enhances their performance, current fabrication methods often require complex equipment and time-consuming processes. Herein, we present a novel magnetization-induced self-assembly method to develop a magnetically grown microneedle array as a dielectric layer for flexible capacitive pressure sensors.
View Article and Find Full Text PDFJ Rehabil Assist Technol Eng
January 2025
Department of Electrical and Electronics Engineering, Faculty of Engineering, University of Lagos, Lagos, Nigeria.
The mobility of people with severe visual impairment is limited affecting their comfort and productivity. There are about 45 million people who are blind with global financial burden and annual global cost of productivity estimated to be USD411 billion according to World Health Organization report of 2024. The contributions of the people who are visually impaired to the gross domestic product (GDP) can be enhanced deploying technology.
View Article and Find Full Text PDFBiophys Rev (Melville)
March 2025
School of Physics, Australian Centre for Microscopy and Microanalysis, Sydney Nano Institute, The University of Sydney, Sydney, NSW 2006, Australia.
The accurate detection of x-rays enables broad applications in various fields, including medical radiography, safety and security screening, and nondestructive inspection. Medical imaging procedures require the x-ray detection devices operating with low doses and high efficiency to reduce radiation health risks, as well as expect the flexible or wearable ones that offer more comfortable and accurate diagnosis experiences. Recently, halide perovskites have shown promising potential in high-performance, cost-effective x-ray detection owing to their attractive features, such as strong x-ray absorption, high-mobility-lifetime product, tunable bandgap, fast response, as well as low-cost raw materials, facile processing, and excellent flexibility.
View Article and Find Full Text PDFNeurophotonics
January 2025
California Institute of Technology, Department of Electrical Engineering, Pasadena, California, United States.
Significance: Cerebral blood flow (CBF) and cerebral blood volume (CBV) are key metrics for regional cerebrovascular monitoring. Simultaneous, non-invasive measurement of CBF and CBV at different brain locations would advance cerebrovascular monitoring and pave the way for brain injury detection as current brain injury diagnostic methods are often constrained by high costs, limited sensitivity, and reliance on subjective symptom reporting.
Aim: We aim to develop a multi-channel non-invasive optical system for measuring CBF and CBV at different regions of the brain simultaneously with a cost-effective, reliable, and scalable system capable of detecting potential differences in CBF and CBV across different regions of the brain.
Digit Health
January 2025
Department of Cardiology, Peking University First Hospital, Beijing, China.
Background: Wearables satisfactorily detect atrial fibrillation (AF) longer than 1 hour. Our study aims to evaluate smartwatch performances for long-term AF monitoring, including AF with short durations.
Methods: This prospective study enrolled AF patients from 2020 to 2023.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!