Dose Optimization of Perfusion-derived Response Assessment in Hepatocellular Carcinoma Treated with Transarterial Chemoembolization: Comparison of Volume Perfusion CT and Iodine Concentration.

Acad Radiol

Eberhard Karls University, University Hospital Tübingen, Department of Radiology, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, D-72076 Tübingen, Germany; University Hospital Basel, University of Basel, Department of Radiology, Petersgraben 4, CH-4031 Basel, Switzerland. Electronic address:

Published: September 2019

Rationale And Objectives: We assessed the value of iodine concentration (IC) as a perfusion-derived response marker for hepatocellular carcinoma (HCC) treated with transarterial chemoembolization (TACE) in comparison with volume perfusion computed tomography (VPCT) parameters.

Materials And Methods: Forty-one HCC lesions in 32 patients examined before and after TACE were analyzed retrospectively. VPCT-parameters were calculated and lesion iodine-maps were computed using subtraction of the baseline and the scan 7 seconds after aortic peak enhancement from the corresponding 80 kVp-VPCT data set. Modified RECIST was used as standard response criteria. Comparisons were performed using Student's t test for normal distributed data and Mann-Whitney U test for non-normal distributed data. Additionally, correlation analysis, receiver operating characteristics (ROC) and interreader agreement were assessed.

Results: In responding lesions, mean pre-TACE IC and blood flow (BF) were 131.2 mg/100 mL and 96.7 mL/100 mL/min, decreasing to IC 25.6 mg/100 mL (P < 0.001) and BF 28.5 mL/100 mL/min (P < 0.001) post-TACE. In nonresponding lesions, the values remained almost unchanged: pre-TACE: mean BF 79.3 mL/100 mL/min and mean IC 90.4 mg/100 mL; post-TACE: mean BF 71.3 mL/100 mL/min (n.s.) and mean IC 105.4 mg/100 mL (n.s.). Differences in IC-values revealed a high sensitivity/specificity of 96.7%/81.8%. IC and VPCT-parameters showed strong, positive correlations. Mean volume CT dose index for VPCT was 63.4 mGy and 4.9 mGy for iodine maps.

Conclusion: Thus, IC is a meaningful perfusion marker for local therapy response monitoring in HCC that can be acquired with low radiation dose. This information is important for further therapy response applications using dual and single energy CT.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2018.09.026DOI Listing

Publication Analysis

Top Keywords

ml/100 ml/min
16
perfusion-derived response
8
hepatocellular carcinoma
8
treated transarterial
8
transarterial chemoembolization
8
comparison volume
8
volume perfusion
8
iodine concentration
8
distributed data
8
therapy response
8

Similar Publications

Mild traumatic brain injuries (TBIs) are frequent in the European population. The pathophysiological changes after TBI include metabolic changes, but these are not observable using current clinical tools. We aimed to evaluate multinuclear MRI as a mean of assessing these changes.

View Article and Find Full Text PDF

Objective: We aimed to quantitatively analyze the perfusion characteristics of pancreatic neuroendocrine tumors (pNETs) utilizing dual-source CT imaging.

Methods: Dual-source CT perfusion scans were obtained from patients with pNETs confirmed by surgical or biopsy pathology. Perfusion parameters, including blood flow (BF), blood volume (BV), capillary permeability surface (PS), mean transit time (MTT), contrast transit time to the start (TTS), and contrast transit time to the peak (TTP), were statistically analyzed and compared with nearby healthy tissue.

View Article and Find Full Text PDF
Article Synopsis
  • Differentiating liver tumors is crucial for appropriate treatment and prognosis, but non-invasive methods often struggle due to overlapping features in imaging.
  • This study evaluated CT perfusion parameters in 48 patients to help distinguish hepatocellular carcinoma (HCC) from other liver tumors, using statistical analysis to identify significant perfusion metrics.
  • Results indicated that blood volume (BV) was particularly effective in differentiating HCC from other tumors, achieving a sensitivity of 96.6% and specificity of 80% at a threshold of 8.3 ml/100 ml/min, alongside several other significant perfusion parameters.
View Article and Find Full Text PDF

There is paucity of data in the available medical literature regarding the parameters of the volumetric perfusion of pancreas grafts. From 5 February 2016 to 23 December 2021, we performed perfusion computed tomography in 41 patients at different times after simultaneous pancreas and kidney transplantation. The study group consisted of 18 men (44%) and 23 women (56%) with a long history of type 1 diabetes mellitus complicated by terminal chronic renal failure.

View Article and Find Full Text PDF

Sitting-induced impairments in postprandial blood flow are an important link between sedentary behaviour and cardiometabolic disease risk. The objective of this work was to examine the effects of resistance exercise breaks (REB) performed every 30 min during an otherwise sedentary 3-h period on the vasodilatory response to a subsequent oral glucose load in sedentary adults. Twenty-four sedentary adults (27 ± 7 years, 16 females) completed two conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!